Literature DB >> 16539563

Temperature rise during orthodontic bonding with various light-curing units--an in vitro study.

Aslihan Uzel1, Tamer Buyukyilmaz, Mustafa Kayalioglu, Ilter Uzel.   

Abstract

The purpose of this in vitro study was to investigate the temperature changes in the pulp chamber during bracket bonding using three different light sources. Bracket bonding was performed on one lower first premolar and one lower central incisor at two different distances (surface and 10 mm). The measurements were taken with a J-type thermocouple wire, placed in the pulp chamber and connected to a data logger. Analysis of variance revealed that pulp chamber temperature changes were influenced by the light source, the tooth type, and the distance from the tip of the light guide to the bracket surface. Halogen induced significantly higher intrapulpal temperature changes than light-emitting diode and Xenon Plasma Arc (PAC) (P = .000). The temperature increase was significantly higher when the light-guide tip was positioned at the surface of the teeth than at the 10-mm distance with all light-curing units (P = .000). All light-curing units produced higher intrapulpal temperature increase in the mandibular incisor than in the premolar. Power PAC produced significantly higher heat changes in the incisor than in the premolar. Orthodontic bonding with different light-curing units did not exceed the critical 5.5 degrees C value for pulpal health.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16539563     DOI: 10.1043/0003-3219(2006)076[0330:TRDOBW]2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  6 in total

1.  Influence of various polishing methods on pulp temperature : an in vitro study.

Authors:  S Mank; M Steineck; L Brauchli
Journal:  J Orofac Orthop       Date:  2011-10-06       Impact factor: 1.938

2.  Effects of High-Energy Curing Lights on Time-Dependent Temperature Changes of Pulp Space During Orthodontic Bonding.

Authors:  Nisa Gül Amuk; Gökmen Kurt; Özgür Er; Gülşen Çakmak; Veysel Aslantaş
Journal:  Turk J Orthod       Date:  2019-03-01

3.  Temperature rise caused in the pulp chamber under simulated intrapulpal microcirculation with different light-curing modes.

Authors:  Sabri Ilhan Ramoglu; Hilal Karamehmetoglu; Tugrul Sari; Serdar Usumez
Journal:  Angle Orthod       Date:  2014-10-15       Impact factor: 2.079

4.  A comparative evaluation of the retention of metallic brackets bonded with resin-modified glass ionomer cement under different enamel preparations: A pilot study.

Authors:  Padmaja Sharma; Ashima Valiathan; Ankit Arora; Sachin Agarwal
Journal:  Contemp Clin Dent       Date:  2013-04

5.  Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp.

Authors:  Firdevs Kahvecioglu; Gül Tosun; Hayriye Esra Ülker
Journal:  Biomed Res Int       Date:  2016-12-20       Impact factor: 3.411

6.  Temperature Rises in the Pulp Chamber with Different Techniques of Orthodontic Adhesive Removal.

Authors:  Maurício Barbieri Mezomo; Juliana Abreu; Juliana Weber; Renato Dalla Porta Garcia; José Antônio Poli Figueiredo; Eduardo Martinelli de Lima
Journal:  Iran Endod J       Date:  2017
  6 in total