Literature DB >> 16537982

A statistical test to determine the quality of accelerometer data.

J E Slaven1, M E Andrew, J M Violanti, C M Burchfiel, B J Vila.   

Abstract

Accelerometer data quality can be inadequate due to data corruption or to non-compliance of the subject with regard to study protocols. We propose a simple statistical test to determine if accelerometer data are of good quality and can be used for analysis or if the data are of poor quality and should be discarded. We tested several data evaluation methods using a group of 105 subjects who wore Motionlogger actigraphs (Ambulatory Monitoring, Inc.) over a 15 day period to assess sleep quality in a study of health outcomes associated with stress among police officers. Using leave-one-out cross-validation and calibration-testing methods of discrimination statistics, error rates for the methods ranged from 0.0167 to 0.4046. We found that the best method was to use the overall average distance between consecutive time points and the overall average mean amplitude of consecutive time points. These values gave us a classification error rate of 0.0167. The average distance between points is a measure of smoothness in the data, and the average mean amplitude between points gave an average reading. Both of these values were then normed to determine a final statistic, K, which was then compared to a cut-off value, K(C), to determine data quality.

Mesh:

Year:  2006        PMID: 16537982     DOI: 10.1088/0967-3334/27/4/007

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Effects of a Community-based Lifestyle Intervention on Change in Physical Activity Among Economically Disadvantaged Adults With Prediabetes.

Authors:  Laura M Hays; Helena M Hoen; James E Slaven; Emily A Finch; David G Marrero; Chandan Saha; Ronald T Ackermann
Journal:  Am J Health Educ       Date:  2016-08-30

2.  Nighttime sleep and physical activity in 6-7 month-old infants.

Authors:  Agnes G Bucko; Marsha Dowda; Edward A Frongillo; Myriam E Torres; Russell R Pate
Journal:  Infant Behav Dev       Date:  2021-08-12

3.  Associations of objectively measured and self-reported sleep duration with carotid artery intima media thickness among police officers.

Authors:  Claudia C Ma; Cecil M Burchfiel; Luenda E Charles; Joan M Dorn; Michael E Andrew; Ja Kook Gu; Parveen Nedra Joseph; Desta Fekedulegn; James E Slaven; Tara A Hartley; Anna Mnatsakanova; John M Violanti
Journal:  Am J Ind Med       Date:  2013-08-22       Impact factor: 2.214

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.