Literature DB >> 16537976

A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS.

Claire Turner1, Patrik Spanel, David Smith.   

Abstract

Selected ion flow tube mass spectrometry, SIFT-MS, has been used to monitor the volatile compounds in the exhaled breath of 30 volunteers (19 males, 11 females) over a 6 month period. Volunteers provided breath samples each week between 8:45 am and 1 pm (before lunch), and the concentrations of several trace compounds were obtained. In this paper the focus is on ammonia, acetone and propanol. It was found that the concentration distributions of these compounds in breath were close to log-normal. The median ammonia level estimated as a geometric mean for all samples was 833 parts per billion (ppb) with a multiplicative standard deviation of 1.62, the values ranging from 248 to 2935 ppb. Breath ammonia clearly increased with increasing age in this volunteer cohort. The geometric mean acetone level for all samples was 477 parts per billion (ppb) with a multiplicative standard deviation of 1.58, the values ranging from 148 to 2744 ppb. The median propanol level for all samples was 18 ppb, the values ranging from 0 to 135 ppb. A weak but significant correlation between breath propanol and acetone levels is apparent in the data. The findings indicate the potential value of SIFT-MS as a non-invasive breath analysis technique for investigating volatile compounds in human health and in the diseased state.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16537976     DOI: 10.1088/0967-3334/27/4/001

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  35 in total

1.  Membrane inlet mass spectrometry for homeland security and forensic applications.

Authors:  Stamatios Giannoukos; Boris Brkić; Stephen Taylor; Neil France
Journal:  J Am Soc Mass Spectrom       Date:  2014-11-15       Impact factor: 3.109

2.  A Handheld, Colorimetric Optoelectronic Dynamics Analyzer for Measuring Total Ammonia of Biological Samples.

Authors:  Nai-Yuan Liu; Pinar Cay-Durgun; Tianmiao Lai; Mark Sprowls; Leslie Thomas; Mary Laura Lind; Erica Forzani
Journal:  IEEE J Transl Eng Health Med       Date:  2018-07-05       Impact factor: 3.316

Review 3.  When kidneys and lungs suffer together.

Authors:  Claudio Sorino; Nicola Scichilone; Claudio Pedone; Stefano Negri; Dina Visca; Antonio Spanevello
Journal:  J Nephrol       Date:  2018-12-06       Impact factor: 3.902

4.  Real-Time Quantitative Analysis of Valproic Acid in Exhaled Breath by Low Temperature Plasma Ionization Mass Spectrometry.

Authors:  Xiaoxia Gong; Songyue Shi; Gerardo Gamez
Journal:  J Am Soc Mass Spectrom       Date:  2016-11-09       Impact factor: 3.109

5.  A Negative Correlation Between Blood Glucose and Acetone Measured in Healthy and Type 1 Diabetes Mellitus Patient Breath.

Authors:  Artur Rydosz
Journal:  J Diabetes Sci Technol       Date:  2015-02-17

6.  Breath-ammonia testing of healthy subjects and patients with cirrhosis.

Authors:  R Adrover; D Cocozzella; E Ridruejo; A García; J Rome; J J Podestá
Journal:  Dig Dis Sci       Date:  2011-08-13       Impact factor: 3.199

Review 7.  Noninvasive monitoring of glucose levels: is exhaled breath the answer?

Authors:  Kiera Roberts; Adam Jaffe; Charles Verge; Paul S Thomas
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

8.  Selected ion flow tube mass spectrometry for targeted analysis of volatile organic compounds in human breath.

Authors:  Ilaria Belluomo; Piers R Boshier; Antonis Myridakis; Bhamini Vadhwana; Sheraz R Markar; Patrik Spanel; George B Hanna
Journal:  Nat Protoc       Date:  2021-06-04       Impact factor: 13.491

9.  Portable Electronic Nose for Analyzing the Smell of Nasal Secretions in Calves: Toward Noninvasive Diagnosis of Infectious Bronchopneumonia.

Authors:  Tatiana Kuchmenko; Anastasiia Shuba; Ruslan Umarkhanov; Anton Chernitskiy
Journal:  Vet Sci       Date:  2021-04-27

10.  Variation in Exhaled Acetone and Other Ketones in Patients Undergoing Bariatric Surgery: a Prospective Cross-sectional Study.

Authors:  Piers R Boshier; Matyas Fehervari; Sheraz R Markar; Sanjay Purkayastha; Patrik Spanel; David Smith; George B Hanna
Journal:  Obes Surg       Date:  2018-08       Impact factor: 4.129

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.