Literature DB >> 16536773

Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound.

Axel Häcker1, Maurice S Michel, Ernst Marlinghaus, Kai U Köhrmann, Peter Alken.   

Abstract

OBJECTIVE: To investigate the safety and the effects on healthy renal tissue of high-intensity focused ultrasound (HIFU) applied extracorporeally. PATIENTS,
MATERIALS AND METHODS: Ultrasound waves (1.04 MHz) created by a cylindrical piezo-ceramic element were focused by a parabolic reflector to a physical focus size of 32 x 4 mm (-6 dB). For an in vivo study, HIFU was applied to the healthy tissue of 24 kidneys, monitored by ultrasonography, with a maximum power of 400 W and a spatially averaged intensity (ISAL) in the focus of 1192 W/cm(2). Fourteen kidneys were removed immediately after ablation to evaluate the side-effects and the effects in the focal zone, and 10 kidneys were removed delayed after 1, 7 and 10 days. The clinical study consisted of 19 patients requiring radical nephrectomy for a renal tumour. HIFU was applied to the healthy tissue of 19 kidneys (up to 1600 W, I(SAL) = 4768 W/cm(2)) before proceeding with the radical nephrectomy.
RESULTS: There were no major complications after applying HIFU to the 43 kidneys. Side-effects included skin burns (grade 3) in two patients. During the follow-up there were no further HIFU-specific side-effects. In one case (in vivo study) there was a thermal lesion of the small intestine, which was due to mis-focusing. HIFU effects in the focal zone immediately after application were: interstitial haemorrhages, fibre rupture, shrinking of the collagen fibres, and coagulation necrosis. These effects occurred sporadically, and their number and size did not correspond to the number of HIFU pulses applied. After 7 and 10 days, there was a well-demarcated coagulation necrosis in vivo.
CONCLUSION: Using this device, extracorporeally applied HIFU can ablate healthy kidney tissue in vivo in combination with diagnostic online ultrasonography. The technique is safe and resulted only in minor complications (skin burns). Refinements in the technology are essential to establish HIFU as a noninvasive treatment option that allows complete and reliable tissue ablation.

Entities:  

Mesh:

Year:  2006        PMID: 16536773     DOI: 10.1111/j.1464-410X.2006.06037.x

Source DB:  PubMed          Journal:  BJU Int        ISSN: 1464-4096            Impact factor:   5.588


  17 in total

1.  Novel high-intensity focused ultrasound clamp--potential adjunct for laparoscopic partial nephrectomy.

Authors:  Jonathan D Harper; Anup Shah; Stuart B Mitchell; Yak-Nam Wang; Frank Starr; Michael R Bailey; Lawrence A Crum
Journal:  J Endourol       Date:  2012-09-10       Impact factor: 2.942

Review 2.  High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy.

Authors:  Alexander Copelan; Jason Hartman; Monzer Chehab; Aradhana M Venkatesan
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

Review 3.  Management of small renal masses: a review.

Authors:  Mesut Remzi; Elchin Javadli; Mehmet Ozsoy
Journal:  World J Urol       Date:  2010-02-23       Impact factor: 4.226

Review 4.  MR thermometry for monitoring tumor ablation.

Authors:  Baudouin Denis de Senneville; Charles Mougenot; Bruno Quesson; Iulius Dragonu; Nicolas Grenier; Chrit T W Moonen
Journal:  Eur Radiol       Date:  2007-05-22       Impact factor: 5.315

5.  Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner.

Authors:  Khaldon Lweesy; Luay Fraiwan; Alaa Shatat; Ghassan Abdo; Abduallah Dawodiah; Mohammad Sameer
Journal:  Med Biol Eng Comput       Date:  2009-12-10       Impact factor: 2.602

6.  Minimally invasive ablation of a toxic thyroid nodule by high-intensity focused ultrasound.

Authors:  O Esnault; A Rouxel; E Le Nestour; G Gheron; L Leenhardt
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-14       Impact factor: 3.825

Review 7.  Renal ablation update.

Authors:  Vishal Khiatani; Robert G Dixon
Journal:  Semin Intervent Radiol       Date:  2014-06       Impact factor: 1.513

8.  High intensity focused ultrasound treatment of small renal masses: Clinical effectiveness and technological advances.

Authors:  G Nabi; C Goodman; A Melzer
Journal:  Indian J Urol       Date:  2010-07

Review 9.  [Energy ablative therapy of renal tumours].

Authors:  H C Klingler
Journal:  Urologe A       Date:  2007-05       Impact factor: 0.639

10.  Current status of ablative therapies for renal tumors.

Authors:  Adam C Mues; Jaime Landman
Journal:  Indian J Urol       Date:  2009 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.