Literature DB >> 16536344

The effect of light-curing source and mode on microtensile bond strength to bovine dentin.

Cristiane Mariote Amaral1, Alessandra Rezende Peris, Glaucia Maria Bovi Ambrosano, Edward J Swift, Luiz André Freire Pimenta.   

Abstract

PURPOSE: The purpose of this study was to evaluate the effects of different light-curing techniques on the microtensile bond strength of hybrid and packable resin composite to dentin. The null hypotheses were that different light-curing techniques do not affect the adhesion of resin composites to tooth structure and that different resin composites do not have a similar bond to dentin.
MATERIALS AND METHODS: One hundred four box-shaped buccal preparations were made and dentin/enamel adhesive was applied according to the manufacturer's instructions (Single Bond 3M ESPE). A hybrid resin composite (Filtek Z250, A2, 3M ESPE) or a packable resin composite (Solitaire 2, A2, Heraeus Kulzer) were inserted in bulk and polymerized using one of these techniques (n = 13): (a) Soft-start (SS) using a halogen lamp (QTH); (b) LED low intensity; (c) Plasma arc (PAC) curing for 6 s for packable resin composite and 3 s for the hybrid resin composite; (d) Conventional (C) QTH curing for 40 s. Afterwards, specimens were thermocycled 1,000 times between 5 degrees C and 55 degrees C in tap water, and were sectioned into beams with a rectangular cross-sectional area of approximately 1 mm2. Microtensile bond strength testing was performed using a universal testing machine at a crosshead speed of 0.5 mm/min.
RESULTS: Bond strength means +/- (SD) in MPa were: Filtek Z250: SSQTH = 17.9 (5.4); LED = 17.9 (6.4); PAC = 16.8 (6.8); CQTH = 16.1 (4.6). Solitaire 2: SSQTH = 12.4 (6.4); LED = 15.5 (4.3); PAC = 16.2 (4.4); CQTH = 13.8 (5.7). The data were structured in a split-plot design and analyzed by a two-way ANOVA and Tukey's tests (alpha = 0.05).
CONCLUSION: The light-curing method did not significantly affect bond strengths. However, the bond strengths of the packable resin composite were significantly lower than those of the hybrid resin composite for all polymerization techniques, suggesting that the restorative material itself might be a more critical factor in adhesion than the curing method.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16536344

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  2 in total

1.  An in vitro evaluation of shear bond strength of silorane and bis-GMA resin-based composite using different curing units.

Authors:  Manak Khosla; Neeraj Malhotra; Kundabala Mala
Journal:  J Conserv Dent       Date:  2012-07

2.  Influence of handpiece maintenance sprays on resin bonding to dentin.

Authors:  Toyotarou Sugawara; Atsushi Kameyama; Akiko Haruyama; Takumi Oishi; Nobuyuki Kukidome; Yasuaki Takase; Masatake Tsunoda
Journal:  Clin Cosmet Investig Dent       Date:  2010-03-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.