Literature DB >> 16536108

Corneal characteristics in myopic patients.

Sabong Srivannaboon1, Suksri Chotikavanich.   

Abstract

OBJECTIVES: To evaluate the characteristics of the cornea in myopic patients. MATERIAL AND
METHOD: A retrospective study of 420 eyes in 210 patients who visited the Excimer Laser Surgery Clinic at Siriraj Hospital, Mahidol University from January 1999 to June 2002 was conducted. All cases that were eligible for myopic refractive surgery were included in the present study. A preoperative ocular examination was done in a fashionable method, including manifest refraction and Orbscan Topography to evaluate corneal thickness, corneal curvature and corneal diameter Statistical analysis was performed to identify the characteristics of the cornea in the patients.
RESULTS: The mean age of the patients was 31.66 +/- 7.77 years. (ranging from 16-51). The mean manifest refraction (spherical equivalent) was -4.9 +/- 2.29 diopters (ranging from -0.50 to -13.75). The mean corneal diameter (white to white) was 11.60 mm +/- 0.37 mm (ranging from 10.8-12.9). The thinnest point of the cornea varied from 409 to 597 microns (mean = 522.55) and located mostly in the infero-temporal quadrant of the eye (23.69% in the right and 32.05% in the left). The mean curvature of the corneal was 44.6 +/- 13.8 diopters (ranging from 39.05-47.65). The mean corneal astigmatism was 1.34 +/- 0.71 diopters and 93.96% were with the rule astigmatism. Positive angle kappa was found in 408 eyes (97%) but all cases were within a 0.5 mm horizontal and 0.3 mm vertical radius from the pupillary axis.
CONCLUSION: Characteristics of the cornea in Thai myopic patients were demonstrated in the present study. Most of the cornea showed with the rule astigmatism with positive angle kappa and the thinnest point, located at the infero-temporal quadrant.

Entities:  

Mesh:

Year:  2005        PMID: 16536108

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  5 in total

1.  Evaluation of myopic corneal diameter with the Orbscan II Topography System.

Authors:  Yi Zha; Wangqiang Feng; Xiaohui Han; Jianqiu Cai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-02       Impact factor: 3.117

2.  White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Masoud Shafiee; Asieh Ehsaei
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

3.  The distribution of orbscan indices in young population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Negareh Yazdani; Hadi Ostadimoghaddam; Payam Nabovati; Raheleh Moravej; AbbasAli Yekta
Journal:  J Curr Ophthalmol       Date:  2016-08-31

4.  Study of distribution of white-to-white corneal diameter and anterior chamber depth in study population obtained with optical biometry using intraocular lens (IOL) master.

Authors:  Kritika Singh; Sandeep Gupta; P S Moulick; Neeraj Bhargava; Alok Sati; Gagandeep Kaur
Journal:  Med J Armed Forces India       Date:  2018-08-14

Review 5.  Angle Kappa and its importance in refractive surgery.

Authors:  Majid Moshirfar; Ryan N Hoggan; Valliammai Muthappan
Journal:  Oman J Ophthalmol       Date:  2013-09
  5 in total