Literature DB >> 16531861

Percutaneous placement of iliosacral screws for unstable pelvic ring injuries: comparison between one and two C-arm fluoroscopic techniques.

Kuo-Ti Peng1, Kuo-Chin Huang, Min-Chi Chen, Yen-Yao Li, Robert Wen-Wei Hsu.   

Abstract

BACKGROUND: This study compares the efficacy and safety of percutaneous placement of iliosacral screws between one and two C-arm fluoroscope groups.
METHODS: This case series contains consecutive 18 unstable pelvic injuries, which were treated with percutaneous placement of iliosacral screws. A single orthopaedic surgeon (K.-T.P.) operated on all these patients. The patients were divided into two groups on the basis of the method of radiographic control. In group 1 (10 patients), iliosacral screws were introduced under the assistance of one C-arm fluoroscope. In group 2 (eight patients), percutaneous placements of iliosacral screws were performed under the control of two sets of fluoroscope.
RESULTS: There were neither clinical complications nor malpositioned screws in both groups. The median time from initial preparation to completion of the first screw insertion was 45.0 and 16.0 minutes for groups 1 and 2, respectively; the radiation exposure was 5.7 and 4.5 minutes, respectively. The differences between groups were statistically significant (p<0.001).
CONCLUSIONS: The use of two sets of fluoroscope provides a speedier method with less radiation exposure for percutaneous placement of iliosacral screws than the use of one set.

Entities:  

Mesh:

Year:  2006        PMID: 16531861     DOI: 10.1097/01.ta.0000200860.01931.9a

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  12 in total

1.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

Review 2.  [Pelvic ring fractures in the elderly. Underestimated osteoporotic fracture].

Authors:  T Fuchs; U Rottbeck; V Hofbauer; M Raschke; R Stange
Journal:  Unfallchirurg       Date:  2011-08       Impact factor: 1.000

3.  [Operative treatment of traumatic fractures of the thorax and lumbar spine. Part II: surgical treatment and radiological findings].

Authors:  M Reinhold; C Knop; R Beisse; L Audigé; F Kandziora; A Pizanis; R Pranzl; E Gercek; M Schultheiss; A Weckbach; V Bühren; M Blauth
Journal:  Unfallchirurg       Date:  2009-02       Impact factor: 1.000

4.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

5.  Procedural Outcomes of Double Vs. Single Fluoroscopy for Fixing Supracondylar Humerus Fractures in Children: A Case-Control Study.

Authors:  Burak Gunaydın; Ali Turgut; Abdulkadir Sarı; Yaşar Mahsut Dinçel; Cagatay Tekin; Yavuz Selim Kabukcuoglu
Journal:  Indian J Orthop       Date:  2020-05-31       Impact factor: 1.251

6.  Minimally invasive reduction of vertically displaced sacral fracture without use of traction table.

Authors:  Alberto Nicodemo; Claudio Cuocolo; Marcello Capella; Martino Deregibus; Alessandro Massè
Journal:  J Orthop Traumatol       Date:  2011-02-24

7.  Biomechanical Comparison of Two Kinds of Internal Fixation in a Type C Zone II Pelvic Fracture Model.

Authors:  Tao Wu; Wei Chen; Qi Zhang; Zhan-Le Zheng; Hong-Zhi Lyu; Yun-Wei Cui; Xiao-Dong Cheng; Ying-Ze Zhang; Yan-Jiang Yang
Journal:  Chin Med J (Engl)       Date:  2015-09-05       Impact factor: 2.628

8.  Percutaneous Placement of Iliosacral Screws Under the Guidance of Axial View Projection of the S1 Pedicle: a Case Series.

Authors:  Yingchao Yin; Zhiyong Hou; Ruipeng Zhang; Lin Jin; Wei Chen; Yingze Zhang
Journal:  Sci Rep       Date:  2017-08-11       Impact factor: 4.379

9.  A screw-view model of navigation aid retrograde transpubic screw fixation for anterior pelvic ring fracture: A case report with 28 months follow-up and technical note.

Authors:  Tong Yu; Yang Qu; Xi-Wen Zhang; Yao Wang; Qi-Yao Jiang; Zhen-De Jiang; Xiu-Jie Zhu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.889

10.  A novel computer navigation method for accurate percutaneous sacroiliac screw implantation: A technical note and literature review.

Authors:  Tong Yu; Shuang Zheng; Xiwen Zhang; Dongsheng Wang; Mingyang Kang; Rongpeng Dong; Yang Qu; Jianwu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.