Literature DB >> 16531807

Combined assessment of left ventricular perfusion and function by gated single-photon emission computed tomography for the risk stratification of high-risk hypertensive patients.

Riccardo Bigi1, Alberto Bestetti, Aldo Strinchini, Antonio Conte, Dario Gregori, Bruno Brusoni, Cesare Fiorentini.   

Abstract

OBJECTIVE: This study was aimed at verifying whether combined information on left ventricular perfusion and function by electrocardiogram-gated single-photon emission computed tomography (SPECT) retains its known prognostic value in patients with systemic hypertension.
METHODS: A total of 415 hypertensive patients underwent rest and stress (exercise in 278 and dipyridamole in 137) gated 99mTc-sestamibi SPECT and prospective follow-up for the composite endpoint of death and acute coronary syndrome. Patients undergoing revascularization were censored. The individual effect of clinical and stress imaging data on outcome was evaluated by Cox regression analysis. Model validation was performed using bootstrap methods adjusted by the degree of optimism in estimates. Survival analysis was performed using the product-limit Kaplan-Meier method.
RESULTS: During a median follow-up of 24 months, 12 cardiac deaths and 32 acute coronary syndromes occurred. After adjusting for the most significant covariates, age [hazard ratio (HR) 1.62, 95% confidence interval (CI) 1.02-2.57], diabetes (HR 7.51, 95% CI 1.61-35.2), summed stress score (HR 2.06, 95% CI 1.07-4), and peak end-systolic volume (HR 3.62, 95% CI 1.35-9.69) were multivariable predictors of outcome. The normal perfusion pattern was associated with a low event rate independently of peak end-systolic volume. Conversely, in the case of moderate to severe perfusion abnormalities, a peak end-systolic volume greater than 74 ml was able to identify an increased risk of adverse outcome. Moreover, peak end-systolic volume was significantly higher among patients who died of a cardiac cause compared with those with different outcomes.
CONCLUSION: A combined assessment of left ventricular perfusion and function by gated SPECT significantly improves risk stratification in hypertensive patients.

Entities:  

Mesh:

Year:  2006        PMID: 16531807     DOI: 10.1097/01.hjh.0000217861.12617.33

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  6 in total

Review 1.  The hypertensive heart. An integrated understanding informed by imaging.

Authors:  Subha V Raman
Journal:  J Am Coll Cardiol       Date:  2010-01-12       Impact factor: 24.094

Review 2.  Mechanisms of load dependency of myocardial ischemia reperfusion injury.

Authors:  Mahmood S Mozaffari; Jun Yao Liu; Worku Abebe; Babak Baban
Journal:  Am J Cardiovasc Dis       Date:  2013-11-01

3.  Prediction of 8-year cardiovascular outcomes in patients with systemic arterial hypertension: value of stress (99m)Tc-tetrofosmin myocardial perfusion imaging in a high-risk cohort.

Authors:  Marisa C G Tjong Joe Wai; Machiel J M Ottenhof; Hendrik J Boiten; Roelf Valkema; Ron T van Domburg; Arend F L Schinkel
Journal:  J Nucl Cardiol       Date:  2013-10-17       Impact factor: 5.952

Review 4.  The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene.

Authors:  Roberto Sciagrà
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07       Impact factor: 10.057

Review 5.  Basal Septal Hypertrophy as the Early Imaging Biomarker for Adaptive Phase of Remodeling Prior to Heart Failure.

Authors:  Fatih Yalçin; Hulya Yalçin; Nagehan Küçükler; Serbay Arslan; Oguz Akkuş; Alparslan Kurtul; Maria Roselle Abraham
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

Review 6.  Hemodynamic stress and microscopic remodeling.

Authors:  Fatih Yalçin; Hulya Yalçin; Roselle Abraham; Theodore P Abraham
Journal:  Int J Cardiol Cardiovasc Risk Prev       Date:  2021-11-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.