Literature DB >> 16530774

Fusion of radiostereometric analysis data into computed tomography space: application to the elbow joint.

A Ericson1, A Arndt, A Stark, M E Noz, G Q Maguire, M P Zeleznik, H Olivecrona.   

Abstract

Improvement of joint prostheses is dependent upon information concerning the biomechanical properties of the joint. Radiostereometric analysis (RSA) and electromagnetic techniques have been applied in previous cadaver and in vivo studies on the elbow joint to provide valuable information concerning joint motion axes. However, such information is limited to mathematically calculated positions of the axes according to an orthogonal coordinate system and is difficult to relate to individual skeletal anatomy. The aim of this study was to evaluate the in vivo application of a new fusion method to provide three-dimensional (3D) visualization of flexion axes according to bony landmarks. In vivo RSA data of the elbow joint's flexion axes was combined with data obtained by 3D computed tomography (CT). Results were obtained from five healthy subjects after one was excluded due to an instable RSA marker. The median error between imported and transformed RSA marker coordinates and those obtained in the CT volume was 0.22 mm. Median maximal rotation error after transformation of the rigid RSA body to the CT volume was 0.003 degrees . Points of interception with a plane calculated in the RSA orthogonal coordinate system were imported into the CT volume, facilitating the 3D visualization of the flexion axes. This study demonstrates a successful fusion of RSA and CT data, without significant loss of RSA accuracy. The method could be used for relating individual motion axes to a 3D representation of relevant joint anatomy, thus providing important information for clinical applications such as the development of joint prostheses.

Entities:  

Mesh:

Year:  2006        PMID: 16530774     DOI: 10.1016/j.jbiomech.2006.01.019

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

2.  A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients.

Authors:  Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Uldis Kesteris; Lars Weidenhielm
Journal:  J Orthop Surg Res       Date:  2016-02-24       Impact factor: 2.359

3.  Are CT Scans a Satisfactory Substitute for the Follow-Up of RSA Migration Studies of Uncemented Cups? A Comparison of RSA Double Examinations and CT Datasets of 46 Total Hip Arthroplasties.

Authors:  Volker Otten; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Kjell G Nilsson; Henrik Olivecrona
Journal:  Biomed Res Int       Date:  2017-01-24       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.