OBJECTIVES: To develop a noninvasive method for the detection of renal transplant rejection using ProteinChip Arrays (surface-enhanced laser desorption/ionization time-of-flight mass spectrometry). METHODS: A total of 23 urine samples were collected from 13 patients showing biopsy-proven renal allograft rejection and from 10 patients without histologic signs of rejection. All 23 patients had clinical symptoms and signs of acute allograft rejection and underwent renal biopsy. Samples were centrifuged, and supernatants were directly spotted onto the ProteinChip arrays with different chromatographic surfaces. The obtained spectra in a range from 2 to 200 kDa were subjected to bioinformatic analysis using the method of Fuzzy c-means, followed by the establishment of rule bases and evaluation using the relevance index according to Kiendl. RESULTS: Several protein peaks were identified allowing differentiation between rejection and no rejection. Using two different ProteinChip surfaces, we found two biomarkers at 25.71 kDa and 28.13 kDa that gave a diagnostic sensitivity of 90% and 93% and a specificity of 80% (SAX2) and 85% (CM10), respectively. CONCLUSIONS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry appears to be a promising new diagnostic tool for distinguishing renal transplant patients with no rejection from those with acute rejection.
OBJECTIVES: To develop a noninvasive method for the detection of renal transplant rejection using ProteinChip Arrays (surface-enhanced laser desorption/ionization time-of-flight mass spectrometry). METHODS: A total of 23 urine samples were collected from 13 patients showing biopsy-proven renal allograft rejection and from 10 patients without histologic signs of rejection. All 23 patients had clinical symptoms and signs of acute allograft rejection and underwent renal biopsy. Samples were centrifuged, and supernatants were directly spotted onto the ProteinChip arrays with different chromatographic surfaces. The obtained spectra in a range from 2 to 200 kDa were subjected to bioinformatic analysis using the method of Fuzzy c-means, followed by the establishment of rule bases and evaluation using the relevance index according to Kiendl. RESULTS: Several protein peaks were identified allowing differentiation between rejection and no rejection. Using two different ProteinChip surfaces, we found two biomarkers at 25.71 kDa and 28.13 kDa that gave a diagnostic sensitivity of 90% and 93% and a specificity of 80% (SAX2) and 85% (CM10), respectively. CONCLUSIONS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry appears to be a promising new diagnostic tool for distinguishing renal transplant patients with no rejection from those with acute rejection.
Authors: Tara K Sigdel; Amit Kaushal; Marina Gritsenko; Angela D Norbeck; Wei-Jun Qian; Wenzhong Xiao; David G Camp; Richard D Smith; Minnie M Sarwal Journal: Proteomics Clin Appl Date: 2010-01 Impact factor: 3.494
Authors: Håvard Loftheim; Karsten Midtvedt; Anders Hartmann; Anna V Reisæter; Pål Falck; Hallvard Holdaas; Trond Jenssen; Leon Reubsaet; Anders Asberg Journal: Transplant Res Date: 2012-08-31
Authors: Dirk Woetzel; Rene Huber; Peter Kupfer; Dirk Pohlers; Michael Pfaff; Dominik Driesch; Thomas Häupl; Dirk Koczan; Peter Stiehl; Reinhard Guthke; Raimund W Kinne Journal: Arthritis Res Ther Date: 2014-04-01 Impact factor: 5.156