| Literature DB >> 16527477 |
S M A Shibli1, K S Beenakumari, N D Suma.
Abstract
Pure nickel electrodes can be used as biosensors especially for sensing and estimating acetylcholine neurotransmitter. In the present work, a good electrochemical sensor was developed by electroplating nano nickel oxide reinforced nickel on graphite substrate. The morphology of the working electrode surface was studied by using a scanning electron microscope (SEM). The electrochemical and biological performance of the modified electrode was characterized by polarization studies in different media. The present modified electrode showed good sensing performance with a response time as low as 8s during sensing and estimation of acetylcholine. The sensitivity of the modified electrode was 34.88 microA/(microM cm(2)).Entities:
Mesh:
Substances:
Year: 2006 PMID: 16527477 DOI: 10.1016/j.bios.2006.01.020
Source DB: PubMed Journal: Biosens Bioelectron ISSN: 0956-5663 Impact factor: 10.618