Literature DB >> 16527354

Accuracy, repeatability, and clinical application of spherocylindrical automated refraction using time-based wavefront aberrometry measurements.

Steven A Nissman1, Rochelle E Tractenberg, Christopher M Saba, John C Douglas, Jay M Lustbader.   

Abstract

PURPOSE: To evaluate the clinical utility of spherocylindrical automated refraction (AR) based on time-based wavefront technology compared with subjective manifest refraction (MR) for the purpose of prescribing eyeglasses.
DESIGN: Prospective observational case series. PARTICIPANTS: A convenience sample of 105 eyes of 53 patients (ages 19 to 87) with corrected acuity no worse than 20/40(-2).
METHODS: Manifest refraction was performed on all subjects followed by three consecutive wavefront measurements at both a 4-mm and 6-mm optical zone using the 3D Wave OPD Scan ARK 10,000 aberrometer. MAIN OUTCOME MEASURES: Repeatability of multiple consecutive ARs; difference in the sphere, cylinder, and axis of AR compared with MR; difference between the corrected visual acuity based on AR- and MR-derived acuity.
RESULTS: Repeatability analysis showed that the initial wavefront refraction was not significantly different from the mean of the three refractions. At the 4-mm zone, the absolute value (+/- standard deviation) of the difference between the initial AR compared with the MR was 0.34+/-0.28 diopters (D) for sphere, 0.22+/-0.21 D for cylinder, and 12.5+/-15.8 degrees for axis. At the 6-mm zone, these values were 0.32+/-0.29 D for sphere, 0.25+/-0.24 D for cylinder, and 11.8+/-14.6 degrees for axis. When 4-mm AR visual acuity was superior to MR acuity (19.0% of eyes) it was 0.28+/-0.24 Snellen lines better, and when inferior (53.3% of eyes) it was 0.47+/-0.37 lines worse. When 6-mm AR acuity was superior to MR acuity (16.2% of eyes) it was 0.32+/-0.22 Snellen lines better, and when inferior (60.0% of eyes) it was 0.48+/-0.48 lines worse. The absolute value of the difference in spherical equivalent of the first AR measurement at the 4-mm zone compared with the MR value was 0.33+/-0.23 D, and at the 6-mm zone it was 0.30+/-0.27 D.
CONCLUSIONS: The wavefront-derived AR values reflect the physical optical system, but not necessarily subjectively derived values, and the impact of this disagreement on patient satisfaction is unknown. Future studies evaluating this technology and its role in clinical ophthalmology are warranted.

Entities:  

Mesh:

Year:  2006        PMID: 16527354     DOI: 10.1016/j.ophtha.2005.12.021

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  9 in total

1.  Comparison of refractive assessment by wavefront aberrometry, autorefraction, and subjective refraction.

Authors:  Jeffrey R Bennett; Gina M Stalboerger; David O Hodge; Muriel M Schornack
Journal:  J Optom       Date:  2014-12-11

2.  An evaluation of the Bausch & Lomb Zywave aberrometer.

Authors:  Michael J Dobos; Michael D Twa; Mark A Bullimore
Journal:  Clin Exp Optom       Date:  2009-05       Impact factor: 2.742

3.  Toric intraocular lens versus limbal relaxing incisions for corneal astigmatism after phacoemulsification.

Authors:  Jonathan C Lake; Gustavo Victor; Gerry Clare; Gustavo Jm Porfírio; Ashleigh Kernohan; Jennifer R Evans
Journal:  Cochrane Database Syst Rev       Date:  2019-12-17

4.  Acute effect of cigarette smoking on pupil size and ocular aberrations: a pre- and postsmoking study.

Authors:  Uzeyir Erdem; Fatih C Gundogan; Umut Aslı Dinc; Umit Yolcu; Abdullah Ilhan; Salih Altun
Journal:  J Ophthalmol       Date:  2015-01-29       Impact factor: 1.909

5.  Agreement and Repeatability of Noncycloplegic and Cycloplegic Wavefront-based Autorefraction in Children.

Authors:  Franziska G Rauscher; Heike Lange; Maryam Yahiaoui-Doktor; Helmut Tegetmeyer; Ina Sterker; Andreas Hinz; Siegfried Wahl; Peter Wiedemann; Arne Ohlendorf; Ralf Blendowske
Journal:  Optom Vis Sci       Date:  2019-11       Impact factor: 1.973

6.  Repeatability of Aberrometry-Based Automated Subjective Refraction in Healthy and Keratoconus Subjects.

Authors:  Gonzalo Carracedo; Carlos Carpena-Torres; Cristina Pastrana; Ana Privado-Aroco; María Serramito; Laura Batres
Journal:  J Ophthalmol       Date:  2020-10-30       Impact factor: 1.909

7.  Comparison Between Aberrometry-Based Binocular Refraction and Subjective Refraction.

Authors:  Gonzalo Carracedo; Carlos Carpena-Torres; Maria Serramito; Laura Batres-Valderas; Anahi Gonzalez-Bergaz
Journal:  Transl Vis Sci Technol       Date:  2018-08-03       Impact factor: 3.283

8.  Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers.

Authors:  Zequan Xu; Yanjun Hua; Wei Qiu; Guoqiang Li; Qiang Wu
Journal:  BMC Ophthalmol       Date:  2018-01-27       Impact factor: 2.209

9.  Comparison of Two Wavefront Autorefractors: Binocular Open-Field versus Monocular Closed-Field.

Authors:  Gonzalo Carracedo; Carlos Carpena-Torres; Laura Batres; Maria Serramito; Anahí Gonzalez-Bergaz
Journal:  J Ophthalmol       Date:  2020-01-03       Impact factor: 1.909

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.