Literature DB >> 16525985

Percutaneous vertebral augmentation and reconstruction with an intravertebral mesh and morcelized bone graft.

John C Chiu1, Michael T Stechison.   

Abstract

Percutaneous vertebral augmentation (VA) and reconstruction with intravertebral polyethylene mesh sac (OptiMesh) and morcelized bone graft provided a minimally invasive efficacious and controlled delivery mechanism to stabilize and treat painful osteoporotic, traumatic and neoplastic vertebral compression fractures (VCFs), as well as avoided serious complications from Polymethylmethacrylate (PMMA) of Vertebroplasty and Kyphoplasty. Osteoconductive and osteoinductive and can be used to create biologic vertebral reconstruction. The adjacent vertebra integrity should be more protected by the construct with a similar elasticity and physical characteristics of the morcelized bone, more matched to that of adjacent bone than PMMA. The indications and surgical techniques are described herein.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16525985

Source DB:  PubMed          Journal:  Surg Technol Int        ISSN: 1090-3941


  6 in total

Review 1.  Percutaneous treatment of insufficiency fractures : principles, technique and review of literature.

Authors:  Douglas P Beall; Abhijit Datir; Sharon L D'Souza; Logan S D'Souza; Divya Gunda; John Morelli; Michael Brandon Johnson; Nima Nabavizadeh
Journal:  Skeletal Radiol       Date:  2010-02       Impact factor: 2.199

2.  Percutaneous vertebral augmentation with polyethylene mesh and allograft bone for traumatic thoracolumbar fractures.

Authors:  C Schulz; U Kunz; U M Mauer; R Mathieu
Journal:  Adv Orthop       Date:  2015-01-26

3.  Finite Element Analysis of Unilateral versus Bipedicular Bone-Filling Mesh Container for the Management of Osteoporotic Compression Fractures.

Authors:  Hui Lu; Qichuan Zhang; Fan Ding; Qimei Wu; Rong Liu
Journal:  Biomed Res Int       Date:  2022-02-24       Impact factor: 3.411

4.  Osteogenic scaffolds for bone reconstruction.

Authors:  Ling-Jiang Li; Ning Liu; Jian-Gang Shi; Qing Liu; Lian-Shun Jia; Wen Yuan
Journal:  Biores Open Access       Date:  2012-06

5.  Percutaneous vertebral compression fracture management with polyethylene mesh-contained morcelized allograft bone.

Authors:  Stewart M Kerr; Benjamin Liechty; Ravi Patel; James S Harrop
Journal:  Curr Rev Musculoskelet Med       Date:  2008-06

6.  Evaluation of surgical outcome of Jack vertebral dilator kyphoplasty for osteoporotic vertebral compression fracture-clinical experience of 218 cases.

Authors:  Jin Fan; Yimin Shen; Ning Zhang; Yongxin Ren; Weihua Cai; Lipeng Yu; Naiqing Wu; Guoyong Yin
Journal:  J Orthop Surg Res       Date:  2016-04-30       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.