Literature DB >> 16524327

Acetabular cup geometry and bone-implant interference have more influence on initial periprosthetic joint space than joint loading and surgical cup insertion.

Kevin L Ong1, Jeffrey Lehman, William I Notz, Thomas J Santner, Donald L Bartel.   

Abstract

Environmental variations in patient-dependent and surgical factors were modeled using robust optimization with a finite element acetabular cup-pelvis model. A previously developed statistical optimization scheme was used to: (1) determine the cup geometry and the optimal cup-bone interference that maximized bone-implant contact areas and minimized changes in the gap volume between the implant and bone surface during gait loading and unloading; and (2) determine the relative contributions of design, patient-dependent, and surgical factors to variations in bone-implant contact areas and a change in gap volume. The statistical analyses indicated that the design variables, namely the equatorial diameter and eccentricity, explained most of the variations in the performance measures. Further, the hemispherical designs performed better than the nonhemispherical designs. The 58 mm hemispherical cup, with 2 mm diametral interferences, minimized the change in gap volume and attained 82% and 81% of the maximum predicted total and rim contact areas, respectively. The equatorial diameter and eccentricity, not the patient-dependent and surgical factors, explained most of the variations in the performance measures. Perfect surface apposition was not attained with any of the cup designs.

Entities:  

Mesh:

Year:  2006        PMID: 16524327     DOI: 10.1115/1.2165701

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  4 in total

1.  Deformation of metal-backed acetabular components and the impact of liner thickness in a cadaveric model.

Authors:  David Markel; Judd Day; Ryan Siskey; Imants Liepins; Steven Kurtz; Kevin Ong
Journal:  Int Orthop       Date:  2010-07-13       Impact factor: 3.075

2.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

3.  Comparison of the Primary Stability of Porous Tantalum and Titanium Acetabular Revision Constructs.

Authors:  Nicholas A Beckmann; Rudi G Bitsch; Mareike Schonhoff; Klaus-Arno Siebenrock; Martin Schwarze; Sebastian Jaeger
Journal:  Materials (Basel)       Date:  2020-04-10       Impact factor: 3.623

4.  Titanium Acetabular Component Deformation under Cyclic Loading.

Authors:  Nicholas A Beckmann; Rudi G Bitsch; Theresa Bormann; Steffen Braun; Sebastian Jaeger
Journal:  Materials (Basel)       Date:  2019-12-20       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.