Literature DB >> 16523839

A new formula for intraocular lens power calculation after refractive corneal surgery.

Massimo Camellin, Antonio Calossi.   

Abstract

PURPOSE: When calculating the power of an intraocular lens (IOL) with conventional methods in eyes that have previously undergone refractive surgery, in most cases the power is inaccurate. To minimize these errors, a new IOL power calculation formula was developed.
METHODS: A theoretical formula empirically adjusted two variables: 1) the corneal power and 2) the anterior chamber depth (ACD). From the average curvature of the entrance pupil area, weighted according to the Stiles-Crawford effect, the corneal power is calculated by using a relative keratometric index that is a function of the actual corneal curvature, type of keratorefractive surgery, and induced refractive change. Anterior chamber depth is a function of the preoperative ACD, lens thickness, axial length, and the ACD constant. We used our formula in 20 eyes that previously underwent refractive surgery (photorefractive keratectomy [n = 6], laser subepithelial keratomileusis [n = 3], laser in situ keratomileusis [n = 6], and radial keratotomy [n = 5]) and compared our results to other formulas.
RESULTS: Mean postoperative spherical equivalent refraction was +0.26 diopters (D) (standard deviation [SD] 0.73, range: -1.25 to +/- 1.58 D) using our formula, +2.76 D (SD 1.03, range: +0.94 to +4.47 D) using the SRK II, +1.44 D (SD 0.97, range: +0.05 to +4.01 D) with Binkhorst, 1.83 D (SD 1.00, range: -0.26 to +4.21 D) with Holladay I, and -2.04 D (SD 2.19, range: -7.29 to +1.62 D) with Rosa's method. With our formula, 60% of absolute refractive prediction errors were within 0.50 D, 80% within 1.00 D, and 93% within 1.50 D.
CONCLUSIONS: In this first series of patients, we obtained encouraging results. With a greater number of cases, all statistical adjustments related to the different types of surgery should be improved.

Entities:  

Mesh:

Year:  2006        PMID: 16523839     DOI: 10.3928/1081-597X-20060201-18

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  10 in total

1.  Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery.

Authors:  Megumi Saiki; Kazuno Negishi; Naoko Kato; Hidemasa Torii; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2014-02-25       Impact factor: 2.447

2.  Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy.

Authors:  Yukari Yaguchi; Kazuno Negishi; Megumi Saiki; Hidemasa Torii; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2016-06-08       Impact factor: 2.447

3.  Estimation of intraocular lens power calculation after myopic corneal refractive surgery: using corneal height in anterior segment optical coherence tomography.

Authors:  Dong Hyun Kim; Mee Kum Kim; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2015-05-20

Review 4.  IOL power calculation after corneal refractive surgery.

Authors:  Maddalena De Bernardo; Luigi Capasso; Luisa Caliendo; Francesco Paolercio; Nicola Rosa
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

5.  Intraocular Lens Power Calculation after Refractive Surgery: A Comparative Analysis of Accuracy and Predictability.

Authors:  Byeong Soo Kang; Jeong Mo Han; Joo Youn Oh; Mee Kum Kim; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2017-06-29

6.  Calculation of the Real Corneal Refractive Power after Photorefractive Keratectomy Using Pentacam, When Only the Preoperative Refractive Error is Known.

Authors:  Maddalena De Bernardo; Maria Borrelli; Roberto Imparato; Nicola Rosa
Journal:  J Ophthalmol       Date:  2020-04-01       Impact factor: 1.909

7.  Development of a New Method for Calculating Intraocular Lens Power after Myopic Laser In Situ Keratomileusis by Combining the Anterior-Posterior Ratio of the Corneal Radius of the Curvature with the Double-K Method.

Authors:  Yoshihiko Iida; Kimiya Shimizu; Nobuyuki Shoji
Journal:  J Clin Med       Date:  2022-01-20       Impact factor: 4.241

8.  Clinical Validation of Adjusted Corneal Power in Patients with Previous Myopic Lasik Surgery.

Authors:  Vicente J Camps; David P Piñero; Veronica Mateo; Celia García; Alberto Artola; Rafael Pérez-Cambrodi; Pedro Ruiz-Fortes
Journal:  J Ophthalmol       Date:  2015-10-07       Impact factor: 1.909

9.  Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

Authors:  Hany A Helaly; Mohammad A M El-Hifnawy; Mohamed Shafik Shaheen; Amr F Abou El-Kheir
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Jan-Mar

Review 10.  Intraocular lens power calculation in eyes with previous corneal refractive surgery.

Authors:  Giacomo Savini; Kenneth J Hoffer
Journal:  Eye Vis (Lond)       Date:  2018-07-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.