Abstract

A simple, practical method has been developed to correct a spectroradiometer's response for measurement errors arising from the instrument's spectral stray light. By characterizing the instrument's response to a set of monochromatic laser sources that cover the instrument's spectral range, one obtains a spectral stray light signal distribution matrix that quantifies the magnitude of the spectral stray light signal within the instrument. By use of these data, a spectral stray light correction matrix is derived and the instrument's response can be corrected with a simple matrix multiplication. The method has been implemented and validated with a commercial CCD-array spectrograph. Spectral stray light errors after the correction was applied were reduced by 1-2 orders of magnitude to a level of approximately 10(-5) for a broadband source measurement, equivalent to less than one count of the 15-bit-resolution instrument. This method is fast enough to be integrated into an instrument's software to perform real-time corrections with minimal effect on acquisition speed. Using instruments that have been corrected for spectral stray light, we expect significant reductions in overall measurement uncertainties in many applications in which spectrometers are commonly used, including radiometry, colorimetry, photometry, and biotechnology.

Year:  2006        PMID: 16523771     DOI: 10.1364/ao.45.001111

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

1.  Scanning, non-contact, hybrid broadband diffuse optical spectroscopy and diffuse correlation spectroscopy system.

Authors:  Johannes D Johansson; Miguel Mireles; Jordi Morales-Dalmau; Parisa Farzam; Mar Martínez-Lozano; Oriol Casanovas; Turgut Durduran
Journal:  Biomed Opt Express       Date:  2016-01-15       Impact factor: 3.732

2.  Determination of photoluminescence quantum yields in dilute solution using non-monochromatic excitation light.

Authors:  Tarik Aaboub; Aicha Boukhriss; Said Gmouh; Martinus H V Werts
Journal:  Photochem Photobiol Sci       Date:  2022-10-21       Impact factor: 4.328

Review 3.  Measurement Challenges for Medical Image Display Devices.

Authors:  J Penczek; P A Boynton; R Beams; R D Sriram
Journal:  J Digit Imaging       Date:  2021-04-12       Impact factor: 4.056

4.  Comparison of Low Cost Miniature Spectrometers for Volcanic SO(2) Emission Measurements.

Authors:  Euripides P Kantzas; Andrew J S McGonigle; Robert G Bryant
Journal:  Sensors (Basel)       Date:  2009-04-28       Impact factor: 3.576

5.  Spectrally Tunable Sources for Advanced Radiometric Applications.

Authors:  S W Brown; J P Rice; J E Neira; B C Johnson; J D Jackson
Journal:  J Res Natl Inst Stand Technol       Date:  2006-10-01

6.  A Study on Optimal Strategy in Relative Radiometric Calibration for Optical Sensors.

Authors:  Kai Yu; Suhong Liu; Yongchao Zhao
Journal:  Sensors (Basel)       Date:  2017-03-02       Impact factor: 3.576

7.  Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers.

Authors:  A K Gaigalas; Lili Wang; Hua-Jun He; Paul DeRose
Journal:  J Res Natl Inst Stand Technol       Date:  2009-08-01

8.  Penetration and scattering-Two optical phenomena to consider when applying proximal remote sensing technologies to object classifications.

Authors:  Christian Nansen
Journal:  PLoS One       Date:  2018-10-09       Impact factor: 3.240

  8 in total