Literature DB >> 16521386

Influence of cavity dimensions, insertion technique and adhesive system on microleakage of Class V restorations.

Carmem Silvia Costa Pfeifer1, Roberto Ruggiero Braga, Paulo Eduardo Capel Cardoso.   

Abstract

BACKGROUND: The authors evaluated the influence of cavity dimensions, insertion technique and adhesive system on microleakage of Class composite restorations.
METHODS: The authors prepared cylindrical cavities with enamel margins of 3-millimeter diameter by 1-mm depth or 6-mm diameter by 2-mm depth on the labial surface of bovine incisors. They defined experimental groups (n = 15) according to cavity size, insertion technique (bulk or incremental) and adhesive system applied (Single Bond, 3M ESPE, St. Paul, Minn., or Excite, Ivoclar Vivadent, Amherst, N.Y.). They restored preparations with Tetric Ceram (Ivoclar Vivadent). After 36 hours' storage in distilled water at 37 C, specimens were submitted to microleakage using 50 percent silver nitrate as tracer. Teeth were sectioned twice and dye penetration on the axial wall was determined in millimeters.
RESULTS: The authors analyzed the data using analysis of variance/Tukey test (a = .05). For large restorations, the use of Single Bond resulted in higher microleakage than Excite (1.56 +/- standard deviation [SD] 0.26 mm and 0.63 +/- SD 0.56 mm, respectively; P < .001), whereas for small restorations there was no statistical difference between adhesives (Excite: 0.47 +/- SD 0.28 mm; Single Bond: 0.46 +/- SD 0.28 mm).
CONCLUSION: The choice of adhesive system influenced microleakage only for large restorations. Incremental insertion of the composite did not affect dye penetration. CLINICAL IMPLICATIONS: Microleakage of composite restorations cannot be predicted only on the basis of the restorations' dimensions. In large restorations, it also depends on the choice of adhesive system, whereas in small restorations, the adhesive used does not seem to be an influential factor. Incremental insertion did not seem to reduce restorations' microleakage.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16521386     DOI: 10.14219/jada.archive.2006.0145

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  5 in total

1.  To compare the microleakage among experimental adhesives containing nanoclay fillers after the storages of 24 hours and 6 months.

Authors:  Seyed Mostafa Mousavinasab; Mohammad Atai; Bagher Alavi
Journal:  Open Dent J       Date:  2011-03-29

2.  Effect of C-factor and LED Curing Mode on Microleakage of Class V Resin Composite Restorations.

Authors:  Qasem Diefallah Alomari; Kefah Barrieshi-Nusair; Mohammad Ali
Journal:  Eur J Dent       Date:  2011-08

3.  Restoration of noncarious cervical lesions: when, why, and how.

Authors:  Cesar Dos Reis Perez; Mariana Rodrigues Gonzalez; Natália Aráujo Silva Prado; Marianna Sorozini Ferreira de Miranda; Mariana de Andrade Macêdo; Bárbara Monteiro Pessôa Fernandes
Journal:  Int J Dent       Date:  2011-12-18

4.  An In vitro Evaluation of Microleakage Associated with Three Different Compomer Placement Techniques in Primary Molars.

Authors:  Mohita Gupta; Dinesh Rao; Sapna Hegde
Journal:  Contemp Clin Dent       Date:  2017 Jan-Mar

5.  The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

Authors:  Ozge Kam Hepdeniz; Ugur Burak Temel; Muhittin Ugurlu; Ozgur Koskan
Journal:  Eur J Dent       Date:  2016 Apr-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.