Literature DB >> 16519604

Influence of hemolysis on routine clinical chemistry testing.

Giuseppe Lippi1, Gian Luca Salvagno, Martina Montagnana, Giorgio Brocco, Gian Cesare Guidi.   

Abstract

BACKGROUND: Preanalytical factors are the main source of variation in clinical chemistry testing and among the major determinants of preanalytical variability, sample hemolysis can exert a strong influence on result reliability. Hemolytic samples are a rather common and unfavorable occurrence in laboratory practice, as they are often considered unsuitable for routine testing due to biological and analytical interference. However, definitive indications on the analytical and clinical management of hemolyzed specimens are currently lacking. Therefore, the present investigation evaluated the influence of in vitro blood cell lysis on routine clinical chemistry testing.
METHODS: Nine aliquots, prepared by serial dilutions of homologous hemolyzed samples collected from 12 different subjects and containing a final concentration of serum hemoglobin ranging from 0 to 20.6 g/L, were tested for the most common clinical chemistry analytes. Lysis was achieved by subjecting whole blood to an overnight freeze-thaw cycle.
RESULTS: Hemolysis interference appeared to be approximately linearly dependent on the final concentration of blood-cell lysate in the specimen. This generated a consistent trend towards overestimation of alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine, creatine kinase (CK), iron, lactate dehydrogenase (LDH), lipase, magnesium, phosphorus, potassium and urea, whereas mean values of albumin, alkaline phosphatase (ALP), chloride, gamma-glutamyltransferase (GGT), glucose and sodium were substantially decreased. Clinically meaningful variations of AST, chloride, LDH, potassium and sodium were observed in specimens displaying mild or almost undetectable hemolysis by visual inspection (serum hemoglobin < 0.6 g/L). The rather heterogeneous and unpredictable response to hemolysis observed for several parameters prevented the adoption of reliable statistic corrective measures for results on the basis of the degree of hemolysis.
CONCLUSION: If hemolysis and blood cell lysis result from an in vitro cause, we suggest that the most convenient corrective solution might be quantification of free hemoglobin, alerting the clinicians and sample recollection.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16519604     DOI: 10.1515/CCLM.2006.054

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  63 in total

Review 1.  Pre-analytic variability in cardiovascular biomarker testing.

Authors:  Roberto Cemin; Massimo Daves
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

2.  A guide for measurement of circulating metabolic hormones in rodents: Pitfalls during the pre-analytical phase.

Authors:  Maximilian Bielohuby; Sarah Popp; Martin Bidlingmaier
Journal:  Mol Metab       Date:  2012-08-09       Impact factor: 7.422

3.  Standardizing in vitro diagnostics tasks in clinical trials: a call for action.

Authors:  Giuseppe Lippi; Ana-Maria Simundic; Leocadio Rodriguez-Manas; Patrick Bossuyt; Giuseppe Banfi
Journal:  Ann Transl Med       Date:  2016-05

4.  Comparison of normothermic and hypothermic perfusion in porcine kidneys donated after cardiac death.

Authors:  Matthew F Blum; Qiang Liu; Basem Soliman; Paul Dreher; Toshihiro Okamoto; Emilio D Poggio; David A Goldfarb; William M Baldwin; Cristiano Quintini
Journal:  J Surg Res       Date:  2017-04-20       Impact factor: 2.192

5.  Consensus Statement for the Management and Reporting of Haemolysed Specimens.

Authors:  Tony Badrick; Harry Barden; Shaw Callen; Goce Dimeski; Stephanie Gay; Peter Graham; Penny Petinos; Ken Sikaris
Journal:  Clin Biochem Rev       Date:  2016-12

6.  How Much Hemolysis Is Acceptable When Undertaking Deep Lancing for Finger Stick Derived Capillary Plasma Glucose Measurement?

Authors:  Helen Heenan; Helen Lunt; Huan Chan; Chris M Frampton
Journal:  J Diabetes Sci Technol       Date:  2017-01-09

7.  Investigation of the Etiology of Anemia in Thromboangiitis Obliterans.

Authors:  Mohammad Mehdi Akbarin; Hassan Ravari; Ataollah Rajabnejad; Narges Valizadeh; Bahare Fazeli
Journal:  Int J Angiol       Date:  2016-01-12

8.  Pre-analytical requirements.

Authors:  John H Livesey; M Jane Ellis; Margaret J Evans
Journal:  Clin Biochem Rev       Date:  2008-08

9.  Interference testing.

Authors:  Goce Dimeski
Journal:  Clin Biochem Rev       Date:  2008-08

10.  Comparison of Serial Blood Collection by Facial Vein and Retrobulbar Methods in C57BL/6 Mice.

Authors:  Jennifer R Frohlich; Christina N Alarcón; Camille R Toarmino; Anna K Sunseri; Tyler M Hockman
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-06-15       Impact factor: 1.232

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.