Literature DB >> 16517044

Electrical impedance spectroscopy of the cervix in non-pregnant and pregnant women.

Saurabh V Gandhi1, Dawn Walker, Pete Milnes, Soma Mukherjee, Brian H Brown, Dilly O C Anumba.   

Abstract

OBJECTIVES: We sought to validate and measure the electrical impedance of the uterine cervix in non-pregnant and pregnant women by spectroscopy. STUDY
DESIGN: Cervical stromal impedance (CSI) was measured in 50 non-pregnant, 20 1st, 20 2nd and 50 3rd trimester pregnant women. The technique was also validated by comparing in vivo data to a finite element (FE) model of cervical tissue.
RESULTS: CSI agreed well with the FE model and was highly reproducible in all study groups. Mean (S.E.) CSI at 4-819 kHz was higher in pregnant (2.78 +/- 0.09 Omega m) compared to non-pregnant (2.38 +/- 0.07, p < 0.01) women, and in the 3rd trimester (3.08 +/- 0.13) compared to non-pregnant (p < 0.01), 1st trimester (2.42 +/- 0.12, p < 0.001) and 2nd trimester (2.20 +/- 0.05, p < 0.001) pregnant women.
CONCLUSION: Measurement of CSI provides a non-invasive method of assessing cervical tissue characteristics. Cervical extracellular matrix synthesis and leukocyte infiltration may account for the increased tissue impedance noted in the 3rd trimester.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16517044     DOI: 10.1016/j.ejogrb.2005.12.029

Source DB:  PubMed          Journal:  Eur J Obstet Gynecol Reprod Biol        ISSN: 0301-2115            Impact factor:   2.435


  4 in total

1.  Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

Authors:  Saurabh V Gandhi; Dawn C Walker; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2006-11-24       Impact factor: 2.819

2.  Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure.

Authors:  Roobin P Jokhi; Vidita V Ghule; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2009-06-17       Impact factor: 2.819

3.  The role of cervical Electrical Impedance Spectroscopy in the prediction of the course and outcome of induced labour.

Authors:  Roobin P Jokhi; Brian H Brown; Dilly O C Anumba
Journal:  BMC Pregnancy Childbirth       Date:  2009-09-02       Impact factor: 3.007

4.  A Preliminary Exploration of the Placental Position Influence on Uterine Electromyography Using Fractional Modelling.

Authors:  Müfit Şan; Arnaldo Batista; Sara Russo; Filipa Esgalhado; Catarina R Palma Dos Reis; Fátima Serrano; Manuel Ortigueira
Journal:  Sensors (Basel)       Date:  2022-02-22       Impact factor: 3.576

  4 in total