Literature DB >> 16514656

Medial collateral ligament insertion site and contact forces in the ACL-deficient knee.

Benjamin J Ellis1, Trevor J Lujan, Michelle S Dalton, Jeffrey A Weiss.   

Abstract

The objectives of this research were to determine the effects of anterior cruciate ligament (ACL) deficiency on medial collateral ligament (MCL) insertion site and contact forces during anterior tibial loading and valgus loading using a combined experimental-finite element (FE) approach. Our hypothesis was that ACL deficiency would increase MCL insertion site forces at the attachments to the tibia and femur and increase contact forces between the MCL and these bones. Six male knees were subjected to varus-valgus and anterior-posterior loading at flexion angles of 0 degrees and 30 degrees. Three-dimensional joint kinematics and MCL strains were recorded during kinematic testing. Following testing, the MCL of each knee was removed to establish a stress-free reference configuration. An FE model of the femur-MCL-tibia complex was constructed for each knee to simulate valgus rotation and anterior translation at 0 degrees and 30 degrees, using subject-specific bone and ligament geometry and joint kinematics. A transversely isotropic hyperelastic material model with average material coefficients taken from a previous study was used to represent the MCL. Subject-specific MCL in situ strain distributions were used in each model. Insertion site and contact forces were determined from the FE analyses. FE predictions were validated by comparing MCL fiber strains to experimental measurements. The subject-specific FE predictions of MCL fiber stretch correlated well with the experimentally measured values (R2 = 0.95). ACL deficiency caused a significant increase in MCL insertion site and contact forces in response to anterior tibial loading. In contrast, ACL deficiency did not significantly increase MCL insertion site and contact forces in response to valgus loading, demonstrating that the ACL is not a restraint to valgus rotation in knees that have an intact MCL. When evaluating valgus laxity in the ACL-deficient knee, increased valgus laxity indicates a compromised MCL. Copyright 2006 Orthopaedic Research Society

Entities:  

Mesh:

Year:  2006        PMID: 16514656     DOI: 10.1002/jor.20102

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  10 in total

1.  Consideration of growth factors and bio-scaffolds for treatment of combined grade II MCL and ACL injury.

Authors:  Natasha Anoka; John Nyland; Mark McGinnis; Dave Lee; Mahmut Nedim Doral; David N M Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-10       Impact factor: 4.342

Review 2.  Verification, validation and sensitivity studies in computational biomechanics.

Authors:  Andrew E Anderson; Benjamin J Ellis; Jeffrey A Weiss
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-06       Impact factor: 1.763

Review 3.  Clinical assessment of antero-medial rotational knee laxity: a systematic review.

Authors:  Dinesh Sirisena; Enrica Papi; Eleanor Tillett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-27       Impact factor: 4.342

Review 4.  Validation of computational models in biomechanics.

Authors:  H B Henninger; S P Reese; A E Anderson; J A Weiss
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

5.  Finding consistent strain distributions in the glenohumeral capsule between two subjects: implications for development of physical examinations.

Authors:  Nicholas J Drury; Benjamin J Ellis; Jeffrey A Weiss; Patrick J McMahon; Richard E Debski
Journal:  J Biomech       Date:  2010-12-07       Impact factor: 2.712

6.  Finite element modelling of the glenohumeral capsule can help assess the tested region during a clinical exam.

Authors:  Benjamin J Ellis; Nicholas J Drury; Susan M Moore; Patrick J McMahon; Jeffrey A Weiss; Richard E Debski
Journal:  Comput Methods Biomech Biomed Engin       Date:  2010-06       Impact factor: 1.763

7.  Strain measurement in the left ventricle during systole with deformable image registration.

Authors:  Nikhil S Phatak; Steve A Maas; Alexander I Veress; Nathan A Pack; Edward V R Di Bella; Jeffrey A Weiss
Journal:  Med Image Anal       Date:  2008-09-17       Impact factor: 8.545

Review 8.  Finite element models of the human shoulder complex: a review of their clinical implications and modelling techniques.

Authors:  Manxu Zheng; Zhenmin Zou; Paulo Jorge Da Silva Bartolo; Chris Peach; Lei Ren
Journal:  Int J Numer Method Biomed Eng       Date:  2016-03-22       Impact factor: 2.747

9.  Predicting the Effect of Localized ACL Damage on Neighbor Ligament Mechanics via Finite Element Modeling.

Authors:  Alexander Knapp; Lakiesha N Williams
Journal:  Bioengineering (Basel)       Date:  2022-01-28

10.  The evaluation of the role of medial collateral ligament maintaining knee stability by a finite element analysis.

Authors:  Dong Ren; Yueju Liu; Xianchao Zhang; Zhaohui Song; Jian Lu; Pengcheng Wang
Journal:  J Orthop Surg Res       Date:  2017-04-21       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.