Literature DB >> 16513435

On-line coupling of size exclusion chromatography and capillary electrophoresis via solid-phase extraction and a Tee-split interface.

F W Alexander Tempels1, Gerard Wiese, Willy J M Underberg, Govert W Somsen, Gerhardus J de Jong.   

Abstract

An on-line size exclusion chromatography (SEC)-solid-phase extraction (SPE)-capillary electrophoresis (CE) system using a Tee-split interface has been developed for the analysis of peptides in biological fluids. The SEC column fractionates the sample by molecular size and the low-molecular-weight fraction, which contains the peptides, is directed to a C(18) SPE microcolumn, where the peptides are trapped and concentrated. The SPE column is desorbed with 425 nL acetonitrile and the effluent is sent to the Tee-split interface, which hydrodynamically splits (1:40) the flow and, thus, allows appropriate injection of analytes into the CE system. The performance of the system is investigated by the analysis of enkephalins in cerebrospinal fluid (CSF). It is demonstrated that the SEC step efficiently removes potentially interfering proteins, permitting reproducible SPE and CE. The total system provides efficient separations of the enkephalins with plate numbers up to 100,000. Concentration limits of detection (S/N = 3) for the peptides are about 100 ng/mL for injection of 20 microL spiked CSF samples. Plots of enkephalin peak areas versus concentration showed good linearity over the 0.25-10 microg/mL range (R2 > or = 0.985). Repeatability of migration time and peak area was within 2% and 10% R.S.D., respectively.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16513435     DOI: 10.1016/j.jchromb.2006.02.003

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

Review 1.  Capillary electrophoresis in bioanalysis.

Authors:  Vratislav Kostal; Joseph Katzenmeyer; Edgar A Arriaga
Journal:  Anal Chem       Date:  2008-05-17       Impact factor: 6.986

2.  A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer.

Authors:  Xian Huang; Siqi Li; Jerome S Schultz; Qian Wang; Qiao Lin
Journal:  Sens Actuators B Chem       Date:  2009-07-16       Impact factor: 7.460

Review 3.  Review of recent advances in analytical techniques for the determination of neurotransmitters.

Authors:  Maura Perry; Qiang Li; Robert T Kennedy
Journal:  Anal Chim Acta       Date:  2009-09-01       Impact factor: 6.558

Review 4.  Recent developments in CE and CEC of peptides.

Authors:  Václav Kasicka
Journal:  Electrophoresis       Date:  2008-01       Impact factor: 3.535

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.