PURPOSE: To determine whether imaging at 3 T could improve and prolong the tag contrast compared to images acquired at 1.5 T in normal volunteers, and whether such improvement would translate into the ability to perform strain measurements in diastole. MATERIALS AND METHODS: Normal volunteers (N = 13) were scanned at 1.5 T (GE Signa CV/i) and 3.0 T (GE VH/i). An ECG-triggered, segmented k-space, spoiled-gradient-echo grid-tagged sequence was used during cine acquisition. Tag contrast was determined by the difference of the mean signal intensity (SI) of the tagline to the mean SI of the myocardium divided by the standard deviation (SD) of the noise (CNR(tag)). Matched short-axis (SA) slices were analyzed. Strain measurements were performed on images using a 2D strain analysis software program (harmonic phase (HARP)). RESULTS: The average CNR(tag) over the cardiac cycle was superior at 3 T compared to 1.5 T for all slices (3 T: 23.4 +/- 12.1, 1.5 T: 9.8 +/- 8.4; P < 0.0001). This difference remained significant at cycle initiation, end-systole, and the end R-R interval (at cycle termination: 3 T = 14.0 +/- 11.0 vs. 1.5 T = 4.4 +/- 3.5; P < 0.01). Strain measures were obtainable only in early systole for 1.5 T images, but were robust throughout the entire R-R interval for 3 T images. CONCLUSION: Imaging at 3 T had a significant benefit for myocardial tag persistence through the cardiac cycle. The improvement allowed strain analysis to be performed into diastole. 2006 Wiley-Liss, Inc.
PURPOSE: To determine whether imaging at 3 T could improve and prolong the tag contrast compared to images acquired at 1.5 T in normal volunteers, and whether such improvement would translate into the ability to perform strain measurements in diastole. MATERIALS AND METHODS: Normal volunteers (N = 13) were scanned at 1.5 T (GE Signa CV/i) and 3.0 T (GE VH/i). An ECG-triggered, segmented k-space, spoiled-gradient-echo grid-tagged sequence was used during cine acquisition. Tag contrast was determined by the difference of the mean signal intensity (SI) of the tagline to the mean SI of the myocardium divided by the standard deviation (SD) of the noise (CNR(tag)). Matched short-axis (SA) slices were analyzed. Strain measurements were performed on images using a 2D strain analysis software program (harmonic phase (HARP)). RESULTS: The average CNR(tag) over the cardiac cycle was superior at 3 T compared to 1.5 T for all slices (3 T: 23.4 +/- 12.1, 1.5 T: 9.8 +/- 8.4; P < 0.0001). This difference remained significant at cycle initiation, end-systole, and the end R-R interval (at cycle termination: 3 T = 14.0 +/- 11.0 vs. 1.5 T = 4.4 +/- 3.5; P < 0.01). Strain measures were obtainable only in early systole for 1.5 T images, but were robust throughout the entire R-R interval for 3 T images. CONCLUSION: Imaging at 3 T had a significant benefit for myocardial tag persistence through the cardiac cycle. The improvement allowed strain analysis to be performed into diastole. 2006 Wiley-Liss, Inc.
Authors: Wojciech Mazur; Kan N Hor; Joshua T Germann; Robert J Fleck; Hussein R Al-Khalidi; Janaka P Wansapura; Eugene S Chung; Michael D Taylor; John L Jefferies; D Woodrow Benson; William M Gottliebson Journal: Int J Cardiovasc Imaging Date: 2011-01-08 Impact factor: 2.357
Authors: Kan N Hor; Narayan Kissoon; Wojciech Mazur; Resmi Gupta; Richard F Ittenbach; Hussein R Al-Khalidi; Linda H Cripe; Subha V Raman; Michael D Puchalski; William M Gottliebson; D Woodrow Benson Journal: Pediatr Cardiol Date: 2014-08-02 Impact factor: 1.655
Authors: Kan N Hor; Janaka Wansapura; Larry W Markham; Wojciech Mazur; Linda H Cripe; Robert Fleck; D Woodrow Benson; William M Gottliebson Journal: J Am Coll Cardiol Date: 2009-04-07 Impact factor: 24.094
Authors: Daniel Thomas; Katharina Strach; Carsten Meyer; Claas P Naehle; Sebastian Schaare; Sven Wasmann; Hans H Schild; Torsten Sommer Journal: J Cardiovasc Magn Reson Date: 2008-12-18 Impact factor: 5.364