Literature DB >> 16507073

Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals.

E Schäfer1, M Erler, T Dammaschke.   

Abstract

AIM: To compare the shaping ability of Mtwo instruments with K3 and RaCe instruments. Part 1 of this two-part report describes the efficacy of these nickel-titanium instruments in simulated curved root canals.
METHODOLOGY: Simulated canals with 28 degree and 35 degree curves in resin blocks were prepared with Mtwo instruments using a single length technique and with K3 and RaCe instruments using a crowndown preparation technique (n = 20 canals in each case). Pre- and post-instrumentation images were recorded and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 20 measuring points, beginning 1 mm from the endpoint of preparation. Incidence of canal aberrations, preparation time, changes of working length and instrument failures were also recorded. The data were analysed statistically using ANOVA and Student-Newman-Keuls test.
RESULTS: On an average, canals prepared with Mtwo instruments remained better centred compared with those enlarged with K3 or RaCe instruments. Six RaCe instruments, four K3 files and none of the Mtwo instruments fractured during preparation (P > 0.05). In both of the canal types, Mtwo was significantly faster (P < 0.001). It was possible with all types of instruments to control working length as well.
CONCLUSIONS: Mtwo instruments prepared curved canals rapidly, respected original canal curvature well and were safe to use.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16507073     DOI: 10.1111/j.1365-2591.2006.01074.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  42 in total

1.  Comparison of Time Required by D-RaCe, R-Endo and Mtwo Instruments for Retreatment: An in vitro Study.

Authors:  Akansha Garg; Ajay Nagpal; Shashit Shetty; Sunil Kumar; Kamal Krishan Singh; Amit Garg
Journal:  J Clin Diagn Res       Date:  2015-02-01

2.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

3.  Comparative evaluation of instrumentation timing and cleaning efficacy in extracted primary molars using manual and NiTi rotary technique - Invitro study.

Authors:  Rachita Mehlawat; Rishabh Kapoor; Kapil Gandhi; Dipanshu Kumar; Ritika Malhotra; Shilpa Ahuja
Journal:  J Oral Biol Craniofac Res       Date:  2019-03-17

4.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

5.  An ex vivo comparative analysis on shaping ability of four NiTi rotary endodontic instruments using spiral computed tomography.

Authors:  Nitin Maitin; D Arunagiri; Dexter Brave; Shipra Nangalia Maitin; Sandeep Kaushik; Saumya Roy
Journal:  J Conserv Dent       Date:  2013-05

6.  Comparison of two canal preparation techniques using mtwo rotary instruments.

Authors:  Faeze Hamze; Kiamars Honardar; Kiumars Nazarimoghadam
Journal:  Iran Endod J       Date:  2011-11-15

7.  A comparative evaluation on the cleaning and shaping ability of three nickel titanium rotary instruments using computerized tomography - An ex vivo study.

Authors:  Gopal S Narayan; Sokkalingam Mothilal Venkatesan; C S Karumaran; Rajamani Indira; S Ramachandran; M R Srinivasan
Journal:  Contemp Clin Dent       Date:  2012-09

8.  A novel approach in assessment of root canal curvature.

Authors:  Shiva Sadeghi; Vahideh Poryousef
Journal:  Iran Endod J       Date:  2009-10-10

9.  Shaping ability of nickel-titanium rotary instruments in curved root canals.

Authors:  Ali Talati; Saeed Moradi; Maryam Forghani; Ali Monajemzadeh
Journal:  Iran Endod J       Date:  2013-05-01

10.  Efficacy of two rotary systems in removing gutta-percha and sealer from the root canal walls.

Authors:  Bahareh Dadresanfar; Payman Mehrvarzfar; Mohammad Ali Saghiri; Sedigh Ghafari; Zohreh Khalilak; Mehdi Vatanpour
Journal:  Iran Endod J       Date:  2011-05-15