Literature DB >> 16502659

Effects of the frequency and duration of cyclic stress on the mechanical properties of cultured collagen fascicles from the rabbit patellar tendon.

Ei Yamamoto1, Daisuke Kogawa, Susumu Tokura, Kozaburo Hayashi.   

Abstract

The effects of frequency or duration of cyclic stress on the mechanical properties of collagen fascicles were studied by means of in vitro tissue culture experiments. Collagen fascicles of approximately 300 microm in diameter were obtained from rabbit patellar tendons. During culture, cyclic stress having the peak stress of approximately 2 MPa was applied to the fascicles at 1 Hz for 1 hour/day (1 Hz-1 h group), at 1 Hz for 4 hours/day (1 Hz-4 h group), or at 4 Hz for 1 hour/day (4 Hz-1 h group). The frequency of 4 Hz and the duration of 1 hour/day are considered to be similar to those of the in vivo stress applied to fascicles in the intact rabbit patellar tendon. After culture for 1 or 2 weeks, the mechanical properties of the fascicles were determined using a microtensile tester, and were compared to the properties of non-cultured, fresh fascicles (control group) and the fascicles cultured under no load condition (non-loaded group). The tangent modulus and tensile strength of fascicles in the 4 Hz-1 h group were similar to those in the control group; however, the fascicles of the 1 Hz-1 h and 1 Hz-4 h groups had significantly lower values than those of the control group. There was no significant difference in the tensile strength between the 1 Hz-1 h and non-loaded groups, although the strength in the 1 Hz-4 h group was significantly higher than that of the non-loaded group. It was concluded that the frequency and duration of cyclic stress significantly affect the mechanical properties of cultured collagen fascicles. If we apply cyclic stress having the frequency and duration which are experienced in vivo, the biomechanical properties are maintained at control, normal level. Lower frequencies or less cycles of applied force induce adverse effects.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16502659     DOI: 10.1115/1.2073587

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  8 in total

Review 1.  The (dys)functional extracellular matrix.

Authors:  Benjamin R Freedman; Nathan D Bade; Corinne N Riggin; Sijia Zhang; Philip G Haines; Katy L Ong; Paul A Janmey
Journal:  Biochim Biophys Acta       Date:  2015-04-27

2.  Impact of cyclic mechanical stimulation on the expression of extracellular matrix proteins in human primary rotator cuff fibroblasts.

Authors:  Birgit Lohberger; Heike Kaltenegger; Nicole Stuendl; Beate Rinner; Andreas Leithner; Patrick Sadoghi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-21       Impact factor: 4.342

Review 3.  Biomaterials to Mimic and Heal Connective Tissues.

Authors:  Benjamin R Freedman; David J Mooney
Journal:  Adv Mater       Date:  2019-03-25       Impact factor: 30.849

4.  Mechanical loading influences the effects of bisphosphonates on human periodontal ligament fibroblasts.

Authors:  Collin Jacobs; Christian Walter; Thomas Ziebart; Isabelle Dirks; Sabrina Schramm; Sarah Grimm; Elena Krieger; Heinrich Wehrbein
Journal:  Clin Oral Investig       Date:  2014-07-25       Impact factor: 3.573

5.  Dynamic Loading and Tendon Healing Affect Multiscale Tendon Properties and ECM Stress Transmission.

Authors:  Benjamin R Freedman; Ashley B Rodriguez; Ryan J Leiphart; Joseph B Newton; Ehsan Ban; Joseph J Sarver; Robert L Mauck; Vivek B Shenoy; Louis J Soslowsky
Journal:  Sci Rep       Date:  2018-07-18       Impact factor: 4.379

Review 6.  Magnetic biomaterials and nano-instructive tools as mediators of tendon mechanotransduction.

Authors:  Ana M Matos; Ana I Gonçalves; Alicia J El Haj; Manuela E Gomes
Journal:  Nanoscale Adv       Date:  2019-12-05

7.  The long head of the biceps tendon is a suitable cell source for tendon tissue regeneration.

Authors:  Matthias F Pietschmann; Markus U Wagenhäuser; Mehmet F Gülecyüz; Andreas Ficklscherer; Volkmar Jansson; Peter E Müller
Journal:  Arch Med Sci       Date:  2014-06-27       Impact factor: 3.318

Review 8.  Engineering Tendon: Scaffolds, Bioreactors, and Models of Regeneration.

Authors:  Daniel W Youngstrom; Jennifer G Barrett
Journal:  Stem Cells Int       Date:  2015-12-28       Impact factor: 5.443

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.