Literature DB >> 16499551

Intensity correction of fluorescent confocal laser scanning microscope images by mean-weight filtering.

Sang-Chul Lee1, Peter Bajcsy.   

Abstract

This paper addresses the problem of intensity correction of fluorescent confocal laser scanning microscope images. Confocal laser scanning microscope images are frequently used in medicine for obtaining 3D information about specimen structures by imaging a set of 2D cross sections and performing 3D volume reconstruction afterwards. However, 2D images acquired from fluorescent confocal laser scanning microscope images demonstrate significant intensity heterogeneity, for example, due to photo-bleaching and fluorescent attenuation in depth. We developed an intensity heterogeneity correction technique that (a) adjusts the intensity heterogeneity of 2D images, (b) preserves fine structural details and (c) enhances image contrast, by performing spatially adaptive mean-weight filtering. Our solution is obtained by formulating an optimization problem, followed by filter design and automated selection of filtering parameters. The proposed filtering method is experimentally compared with several existing techniques by using four quality metrics: contrast, intensity heterogeneity (entropy) in a low frequency domain, intensity distortion in a high frequency domain and saturation. Based on our experiments and the four quality metrics, the developed mean-weight filtering outperforms other intensity correction methods by at least a factor of 1.5 when applied to fluorescent confocal laser scanning microscope images.

Mesh:

Year:  2006        PMID: 16499551     DOI: 10.1111/j.1365-2818.2006.01546.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  6 in total

1.  3D medical volume reconstruction using web services.

Authors:  Rob Kooper; Andrew Shirk; Sang-Chul Lee; Amy Lin; Robert Folberg; Peter Bajcsy
Journal:  Comput Biol Med       Date:  2008-03-11       Impact factor: 4.589

2.  Spatial quantitation of FISH signals in diploid versus aneuploid nuclei.

Authors:  Amol Shete; Pulivarthi Rao; Debananda Pati; Fatima Merchant
Journal:  Cytometry A       Date:  2013-12-17       Impact factor: 4.355

3.  Toward automated analysis of biofilm architecture: bias caused by extraneous confocal laser scanning microscopy images.

Authors:  Robin T Merod; Jennifer E Warren; Hope McCaslin; Stefan Wuertz
Journal:  Appl Environ Microbiol       Date:  2007-06-01       Impact factor: 4.792

4.  Pipeline for illumination correction of images for high-throughput microscopy.

Authors:  S Singh; M-A Bray; T R Jones; A E Carpenter
Journal:  J Microsc       Date:  2014-09-16       Impact factor: 1.758

5.  Methods for mitochondrial health assessment by High Content Imaging System.

Authors:  Chatnapa Panusatid; Nattachai Thangsiriskul; Chayanon Peerapittayamongkol
Journal:  MethodsX       Date:  2022-04-02

6.  A versatile pipeline for the multi-scale digital reconstruction and quantitative analysis of 3D tissue architecture.

Authors:  Hernán Morales-Navarrete; Fabián Segovia-Miranda; Piotr Klukowski; Kirstin Meyer; Hidenori Nonaka; Giovanni Marsico; Mikhail Chernykh; Alexander Kalaidzidis; Marino Zerial; Yannis Kalaidzidis
Journal:  Elife       Date:  2015-12-27       Impact factor: 8.140

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.