Literature DB >> 16494609

The new Richmond HRR pseudoisochromatic test for colour vision is better than the Ishihara test.

Barry L Cole1, Ka-Yee Lian, Carol Lakkis.   

Abstract

AIM: The Hardy-Rand-Rittler (HRR) pseudoisochromatic test for colour vision is highly regarded but has long been out of print. Richmond Products produced a new edition in 2002 that has been re-engineered to rectify shortcomings of the original test. This study is a validation trial of the new test using a larger sample and different criteria of evaluation from those of the previously reported validation study.
METHODS: The Richmond HRR test was given to 100 consecutively presenting patients with abnormal colour vision and 50 patients with normal colour vision. Colour vision was diagnosed using the Ishihara test, the Farnsworth D15 test, the Medmont C-100 test and the Type 1 Nagel anomaloscope.
RESULTS: The Richmond HRR test has a sensitivity of 1.00 and a specificity of 0.975 when the criterion for failing is two or more errors with the screening plates. Sensitivity and specificity become 0.98 and 1.0, respectively, when the fail criterion is three or more errors. Those with red-green colour vision deficiency were correctly classified as protan or deutan on 86 per cent of occasions, with 11 per cent unclassified and three per cent incorrectly classified. All those graded as having a 'mild' defect by the Richmond HRR test passed the Farnsworth D15 test and had an anomaloscope range of 30 or less. Not all dichromats were classified as 'strong', which was one of the goals of the re-engineering and those graded as 'medium' and 'strong' included dichromats and those who have a mild colour vision deficiency based on the results of the Farnsworth D15 test and the anomaloscope range.
CONCLUSIONS: The test is as good as the Ishihara test for detection of the red-green colour vision deficiencies but unlike the Ishihara, also has plates for the detection of the tritan defects. Its classification of protans and deutans is useful but the Medmont C-100 test is better. Those graded as 'mild' by the Richmond HRR test can be regarded as having a mild colour vision defect but a 'medium' or 'strong' grading needs to be interpreted in conjunction with other tests such as the Farnsworth D15 and the anomaloscope. The Richmond HRR test could be the test of choice for clinicians who wish to use a single test for colour vision.

Entities:  

Mesh:

Year:  2006        PMID: 16494609     DOI: 10.1111/j.1444-0938.2006.00015.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  23 in total

1.  Depth perception in patients with congenital color vision deficiency.

Authors:  Serdar Ozates; Mehmet Ali Sekeroglu; Cagri Ilhan; Sibel Doguizi; Pelin Yilmazbas
Journal:  Eye (Lond)       Date:  2018-12-05       Impact factor: 3.775

2.  Age-corrected reference values for the Heidelberg multi-color anomaloscope.

Authors:  Florian Rüfer; Benno Sauter; Alexa Klettner; Katja Göbel; Josef Flammer; Carl Erb
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-17       Impact factor: 3.117

3.  Using Acute Optic Neuritis Trials to Assess Neuroprotective and Remyelinating Therapies in Multiple Sclerosis.

Authors:  Magí Andorrà; Salut Alba-Arbalat; Anna Camos-Carreras; Iñigo Gabilondo; Elena Fraga-Pumar; Ruben Torres-Torres; Irene Pulido-Valdeolivas; Ana I Tercero-Uribe; Ana M Guerrero-Zamora; Santiago Ortiz-Perez; Irati Zubizarreta; Nuria Sola-Valls; Sara Llufriu; Maria Sepulveda; Eugenia Martinez-Hernandez; Thais Armangue; Yolanda Blanco; Pablo Villoslada; Bernardo Sanchez-Dalmau; Albert Saiz; Elena H Martinez-Lapiscina
Journal:  JAMA Neurol       Date:  2020-02-01       Impact factor: 18.302

4.  Comparison between Hardy-Rand-Rittler 4th edition and Ishihara color plate tests for detection of dyschromatopsia in optic neuropathy.

Authors:  Ruth Huna-Baron; Yoseph Glovinsky; Zohar Habot-Wilner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-13       Impact factor: 3.117

5.  The Effect of ChromaGen Contact Lenses on Corneal Clarity: A Corneal Densitometry.

Authors:  Cagri Ilhan; Mehmet Ali Sekeroglu; Sibel Doguizi; Pelin Yilmazbas
Journal:  Beyoglu Eye J       Date:  2022-05-27

6.  PyPlr: A versatile, integrated system of hardware and software for researching the human pupillary light reflex.

Authors:  Joel T Martin; Joana Pinto; Daniel Bulte; Manuel Spitschan
Journal:  Behav Res Methods       Date:  2021-12-16

7.  Color vision deficiency in a middle-aged population: the Shahroud Eye Study.

Authors:  Ebrahim Jafarzadehpur; Hassan Hashemi; Mohammad Hassan Emamian; Mehdi Khabazkhoob; Shiva Mehravaran; Mohammad Shariati; Akbar Fotouhi
Journal:  Int Ophthalmol       Date:  2014-02-14       Impact factor: 2.031

8.  Color vision impairment in multiple sclerosis points to retinal ganglion cell damage.

Authors:  E J Lampert; M Andorra; R Torres-Torres; S Ortiz-Pérez; S Llufriu; M Sepúlveda; N Sola; A Saiz; B Sánchez-Dalmau; P Villoslada; Elena H Martínez-Lapiscina
Journal:  J Neurol       Date:  2015-08-11       Impact factor: 4.849

9.  Should prospective dental students be screened for colour vision deficits?

Authors:  F Mushtaq; R C Baraas; L M Al-Saud; I Mirghani; C van der Zee; E Yates; A Keeling; M A Mon-Williams; M Manogue
Journal:  Br Dent J       Date:  2016-09-09       Impact factor: 1.626

10.  Comparison of the Richmond HRR 4th edition and Farnsworth-Munsell 100 Hue Test for quantitative assessment of tritan color deficiencies.

Authors:  Katharina G Foote; Maureen Neitz; Jay Neitz
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2014-04-01       Impact factor: 2.129

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.