Literature DB >> 16493172

Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament.

Jon Olav Drogset1, Torbjørn Grøntvedt, Gunnar Myhr.   

Abstract

BACKGROUND: Metal interference screws can cause problems if revision is needed and can interfere with magnetic resonance imaging. Bioabsorbable screws have been developed to prevent these problems, but the rate of resorption and integration is not well understood. HYPOTHESIS: Poly-L-lactic acid interference screws will be resorbed 2 years after anterior cruciate ligament reconstruction. STUDY
DESIGN: Case series; Level of evidence, 4.
METHODS: The study group consisted of 19 patients with isolated anterior cruciate ligament ruptures reconstructed with bone-patellar tendon-bone autografts fixed with poly-L-lactic acid interference screws using an endoscopic technique. Magnetic resonance imaging was used to evaluate resorption of the screws, bony integration of the screws, and integration of the bone blocks after 2 years.
RESULTS: At 2 years, the mean reduction in the volume of the femoral screws was 64% and of the tibial screw was 63%. Bony integration of the femoral bone block was considered good in 17 patients and fair in 2 patients. Integration of the tibial bone block was considered good in 16 patients and fair in 1 patient who demonstrated widening of the tibial tunnel. Osteolysis around the screws was seen in 3 patients in the femur and none in the tibia.
CONCLUSION: The mean reduction in volume of the poly-L-lactic acid screws as measured by magnetic resonance imaging after 2 years was approximately two thirds. The integration of the bone blocks was considered good in 90% of the patients. Osteolysis around the screws was visible in 16% of the patients. CLINICAL RELEVANCE: Two years after ACL reconstruction using poly-L-lactic acid interference screws, the surgeon can expect to find approximately one third of the volume of the screw remaining in the bone tunnels.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16493172     DOI: 10.1177/0363546505285384

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  28 in total

1.  Tibial bone bridge and bone block fixation in double-bundle anterior cruciate ligament reconstruction without hardware: a technical note.

Authors:  R Siebold; H Thierjung; K Cafaltzis; E Hoeschele; J Tao; T Ellert
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-08       Impact factor: 4.342

Review 2.  Multimodality imaging of the postoperative shoulder.

Authors:  Klaus Woertler
Journal:  Eur Radiol       Date:  2007-05-22       Impact factor: 5.315

3.  Biomechanical properties of femoral posterior cruciate ligament fixations.

Authors:  M Ettinger; M Petri; K T Haag; S Brand; A Dratzidis; C Hurschler; C Krettek; M Jagodzinski
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-03       Impact factor: 4.342

4.  [Biodegradable screw versus a press-fit bone plug fixation for ACL reconstruction: a prospective randomized study].

Authors:  B Geiges; C von Falck; K Knobloch; C Haasper; R Meller; C Krettek; S Hankemeier; J Brand; M Jagodzinski
Journal:  Unfallchirurg       Date:  2013-02       Impact factor: 1.000

5.  [Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament].

Authors:  M Ettinger; E Liodakis; C Haasper; C Hurschler; D Breitmeier; C Krettek; M Jagodzinski
Journal:  Unfallchirurg       Date:  2012-09       Impact factor: 1.000

6.  Biomechanical characterization of double-bundle femoral press-fit fixation techniques.

Authors:  M Ettinger; C Haasper; S Hankemeier; C Hurschler; D Breitmeier; C Krettek; M Jagodzinski
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-14       Impact factor: 4.342

Review 7.  Migration of "bioabsorbable" screws in ACL repair. How much do we know? A systematic review.

Authors:  Hélder Pereira; Hélder M D Pereira; Vítor M Correlo; Joana Silva-Correia; Joaquim M Oliveira; Rui L Reis; Rui L Reis Ceng; João Espregueira-Mendes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-03       Impact factor: 4.342

8.  Torsional stability of interference screws derived from bovine bone--a biomechanical study.

Authors:  Joscha Bauer; Turgay Efe; Silke Herdrich; Leo Gotzen; Bilal Farouk El-Zayat; Jan Schmitt; Nina Timmesfeld; Markus Dietmar Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-01       Impact factor: 2.362

9.  Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction.

Authors:  K-H Frosch; T Sawallich; G Schütze; A Losch; T Walde; P Balcarek; F Konietschke; K M Stürmer
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-08-21

Review 10.  Femoral fracture following knee ligament reconstruction surgery due to an unpredictable complication of bioabsorbable screw fixation: a case report and review of literature.

Authors:  Sujith Konan; Fares Sami Haddad
Journal:  J Orthop Traumatol       Date:  2009-12-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.