Literature DB >> 16492432

Noninvasive diagnosis of aortic coarctation in neonates with patent ductus arteriosus.

Chun-Wei Lu1, Jou-Kou Wang, Chung-I Chang, Ming-Tai Lin, En-Ting Wu, Hung-Chi Lue, Yih-Sharng Chen, In-Su Chiu, Mei-Hwan Wu.   

Abstract

OBJECTIVES: To find a noninvasive method to detect coarctation of the aorta (CoA) in the presence of a patent ductus arteriosus (PDA) in neonates. STUDY
DESIGN: From 1994 to 1998, 36 neonates with CoA and PDA confirmed by surgery or cardiac catheterization were studied; another 19 neonates with isolated PDA served as control patients. The prospective study was conducted from 2001 to 2002 on 162 neonates.
RESULTS: Among the 36 neonates in the CoA group, 14 patients (39%) had blood pressure discrepancy, 26 patients (72%) had a visualized posterior shelf by echocardiogram, and the ratio of isthmus/descending aorta diameters (I/D ratio) was below 0.64 in 32 patients (89%). None of the control patients had these features. A diagnostic approach was subsequently proposed, according to which a neonate with PDA who fulfilled any of the above features was diagnosed as CoA plus PDA. In the prospective study, the sensitivity and positive predictive values of this method were both 91.7%, whereas the specificity and negative predictive values were both 99.3%.
CONCLUSIONS: Echocardiographic measurements of I/D ratio along with the delineation of posterior shelf and a BP discrepancy can satisfactorily identify CoA in the presence of PDA in neonates.

Entities:  

Mesh:

Year:  2006        PMID: 16492432     DOI: 10.1016/j.jpeds.2005.09.036

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  3 in total

1.  Unexpected co-arctation of aorta detected by transesophageal echocardiography during patent ductus arteriosus ligation.

Authors:  Fei Liu; Ming-chon Hsiung; Haibo Song; Ke Dian; Hong Tang; Jin Liu
Journal:  Front Med       Date:  2013-05-17       Impact factor: 4.592

2.  A clinical prediction model to estimate the risk for coarctation of the aorta in the presence of a patent ductus arteriosus.

Authors:  Jonathan H Soslow; Ann Kavanaugh-McHugh; Li Wang; Daniel L Saurers; Neeru Kaushik; Stacy A S Killen; David A Parra
Journal:  J Am Soc Echocardiogr       Date:  2013-09-23       Impact factor: 5.251

3.  Doppler echocardiographic indices in aortic coarctation: a comparison of profiles before and after stenting.

Authors:  Shokoufeh Hajsadeghi; Seyed-Mohammad Fereshtehnejad; Mahshid Ojaghi; Hossein Ali Bassiri; Mohammad Reza Keramati; Mitra Chitsazan; Saeid Gholami
Journal:  Cardiovasc J Afr       Date:  2012-10       Impact factor: 1.167

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.