Literature DB >> 16485763

Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes.

Kevin J Otto1, Matthew D Johnson, Daryl R Kipke.   

Abstract

Current neuroprosthetic systems based on electro-physiological recording have an extended, yet finite working lifetime. Some posited lifetime-extension solutions involve improving device biocompatibility or suppressing host immune responses. Our objective was to test an alternative solution comprised of applying a voltage pulse to a microelectrode site, herein termed "rejuvenation." Previously, investigators have reported preliminary electrophysiological results by utilizing a similar voltage pulse. In this study we sought to further explore this phenomenon via two methods: 1) electrophysiology; 2) an equivalent circuit model applied to impedance spectroscopy data. The experiments were conducted via chronically implanted silicon-substrate iridium microelectrode arrays in the rat cortex. Rejuvenation voltages resulted in increased unit recording signal-to-noise ratios (10% +/- 2%), with a maximal increase of 195% from 3.74 to 11.02. Rejuvenation also reduced the electrode site impedances at 1 kHz (67% +/- 2%). Neither the impedance nor recording properties of the electrodes changed on neighboring microelectrode sites that were not rejuvenated. In the equivalent circuit model, we found a transient increase in conductivity, the majority of which corresponded to a decrease in the tissue resistance component (44% +/- 7%). These findings suggest that rejuvenation may be an intervention strategy to prolong the functional lifetime of chronically implanted microelectrodes.

Entities:  

Mesh:

Year:  2006        PMID: 16485763     DOI: 10.1109/TBME.2005.862530

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  42 in total

1.  A system for recording neural activity chronically and simultaneously from multiple cortical and subcortical regions in nonhuman primates.

Authors:  Joseph Feingold; Theresa M Desrochers; Naotaka Fujii; Ray Harlan; Patrick L Tierney; Hideki Shimazu; Ken-Ichi Amemori; Ann M Graybiel
Journal:  J Neurophysiol       Date:  2011-12-14       Impact factor: 2.714

2.  Voltage biasing, cyclic voltammetry, & electrical impedance spectroscopy for neural interfaces.

Authors:  Seth J Wilks; Tom J Richner; Sarah K Brodnick; Daryl R Kipke; Justin C Williams; Kevin J Otto
Journal:  J Vis Exp       Date:  2012-02-24       Impact factor: 1.355

Review 3.  Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording.

Authors:  Anoop C Patil; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-11       Impact factor: 2.602

4.  In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle.

Authors:  Ankur R Shah; Muhammad S Khan; Annie M Hirahara; Matthias Lange; Ravi Ranjan; Derek J Dosdall
Journal:  ACS Biomater Sci Eng       Date:  2020-05-07

5.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

6.  In vivo impedance spectroscopy of deep brain stimulation electrodes.

Authors:  Scott F Lempka; Svjetlana Miocinovic; Matthew D Johnson; Jerrold L Vitek; Cameron C McIntyre
Journal:  J Neural Eng       Date:  2009-06-03       Impact factor: 5.379

7.  Using a common average reference to improve cortical neuron recordings from microelectrode arrays.

Authors:  Kip A Ludwig; Rachel M Miriani; Nicholas B Langhals; Michael D Joseph; David J Anderson; Daryl R Kipke
Journal:  J Neurophysiol       Date:  2008-12-24       Impact factor: 2.714

8.  High-resolution local field potentials measured with deep brain stimulation arrays.

Authors:  Simeng Zhang; Allison T Connolly; Lauren R Madden; Jerrold L Vitek; Matthew D Johnson
Journal:  J Neural Eng       Date:  2018-04-13       Impact factor: 5.379

Review 9.  Physiological properties of brain-machine interface input signals.

Authors:  Marc W Slutzky; Robert D Flint
Journal:  J Neurophysiol       Date:  2017-06-14       Impact factor: 2.714

10.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.