Literature DB >> 16485237

History of peritoneal access development.

Zbylut J Twardowski1.   

Abstract

The first peritoneal accesses were devices that had been used in other fields (general surgery, urology, or gynecology): trocars, rubber catheters, and sump drains. In the period after World War II, numerous papers were published with various modifications of peritoneal dialysis. The majority of cases were treated with the continuous flow technique; rubber catheters for inflow and sump drains for outflow were commonly used. At the end of the 1940s, intermittent peritoneal dialysis started to be more frequently used. Severe complications of peritoneal accesses created incentive to design accesses specifically for peritoneal dialysis. The initial three, in the late 1940s, were modified sump drains; however, Ferris and Odel for the first time designed a soft, polyvinyl intraperitoneal tube with metal weights to keep the catheter tip in the pelvic gutter where the conditions for drain are the best. In the 1950s, intermittent peritoneal dialysis was established as the preferred technique; polyethylene and nylon catheters became commercially available and peritoneal dialysis was established as a valuable method for treatment of acute renal failure. The major breakthrough came in the 1960s. First of all, it was discovered that the silicone rubber was less irritating to the peritoneal membrane than other plastics. Then, it was found that polyester velour allowed an excellent tissue ingrowth creating a firm bond with the tissue. When a polyester cuff was glued to the catheter, it restricted catheter movement and created a closed tunnel between the integument and the peritoneal cavity. In 1968, Tenckhoff and Schechter combined these two features and designed a silicone rubber catheter with a polyester cuff for treatment of acute renal failure and two cuffs for treatment of chronic renal failure. This was the most important development in peritoneal access. Technological evolution never ends. Multiple attempts have been made to eliminate remaining complications of the Tenckhoff catheter such as exit/tunnel infection, external cuff extrusion, migration leading to obstruction, dialysate leaks, recurrent peritonitis, and infusion or pressure pain. New designs combined the best features of the previous ones or incorporated new elements. Not all attempts have been successful, but many have. To prevent catheter migration, Di Paolo and his colleagues applied the old idea of providing weights at the catheter tips to Tenckhoff catheters. In another modification, Twardowski and his collaborators created a permanent bend to the intra-tunnel portion of the silicone catheter to eliminate cuff extrusions. The Tenckhoff catheter continues to be widely used for chronic peritoneal dialysis, although its use is decreasing in favor of swan-neck catheters. Soft, silicone rubber instead of rigid tubing virtually eliminated such early complications as bowel perforation or massive bleeding. Other complications, such as obstruction, pericatheter leaks, and superficial cuff extrusions have been markedly reduced in recent years, particularly with the use of swan-neck catheters and insertion through the rectus muscle instead of the midline. However, these complications still occur, so new designs are being tried.

Entities:  

Mesh:

Year:  2006        PMID: 16485237     DOI: 10.1177/039139880602900102

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  10 in total

1.  The placement of peritoneal dialysis catheters: a prospective randomized comparison of open surgery versus "Mini-Perc" technique.

Authors:  Wei Zhu; Chunming Jiang; Xi Zheng; Miao Zhang; Hongqian Guo; Xiang Yan
Journal:  Int Urol Nephrol       Date:  2014-11-14       Impact factor: 2.370

2.  Development and long-term in vivo testing of a novel skin-button system for preventing driveline infection of an implantable VAD system.

Authors:  Toshihide Mizuno; Yashushi Nemoto; Tomonori Tsukiya; Yoshiaki Takewa; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2011-07-09       Impact factor: 1.731

3.  New peritoneal catheters: new catheter problems?

Authors:  Mercedes Moreiras-Plaza; Isabel Maria Martin-Baez; Raquel Blanco-García; Laura Vanessa Beato-Coo; Cynthia Raquel Cossio-Aranibar
Journal:  Perit Dial Int       Date:  2014 Jul-Aug       Impact factor: 1.756

4.  A modified open surgery technique for peritoneal dialysis catheter placement decreases catheter malfunction.

Authors:  Chunming Jiang; Linfeng Xu; Yun Chen; Xiang Yan; Cheng Sun; Miao Zhang
Journal:  Perit Dial Int       Date:  2014-06       Impact factor: 1.756

5.  A material stress test study on occurrence of leakage and material failure of peritoneal dialysis (PD) catheters.

Authors:  Matthias Klingele; Martin Carstens; Lea Baerens; Matthias W Laschke; Wolfgang Metzger; Danilo Fliser; Clemens M Meier
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.379

6.  Section 5: Dialysis Interventions for Treatment of AKI.

Authors: 
Journal:  Kidney Int Suppl (2011)       Date:  2012-03

7.  Biomechanical and histomorphometric evaluation of skin integration on titanium and PEEK implants with different surface treatments.

Authors:  Per Kjellin; Karin Danielsson; Joakim Håkansson; Karin Agrenius; Therese Andersson; Patrik Stenlund
Journal:  J Mater Sci Mater Med       Date:  2022-09-30       Impact factor: 4.727

8.  A brief recap of tips and surgical manoeuvres to enhance optimal outcome of surgically placed peritoneal dialysis catheters.

Authors:  Jodie H Frost; Atul Bagul
Journal:  Int J Nephrol       Date:  2012-07-19

9.  Clinical application of right low-position modified peritoneal dialysis catheterization.

Authors:  Wei Ren; Wei Chen; Hui-Xuan Pan; Lei Lan; Peng Wang; Ye-Hua Huang; Ming Kong; Yan Wang
Journal:  Exp Ther Med       Date:  2012-11-12       Impact factor: 2.447

Review 10.  Peritoneal Dialysis in Austere Environments: An Emergent Approach to Renal Failure Management.

Authors:  Chad Gorbatkin; John Bass; Fredric O Finkelstein; Steven M Gorbatkin
Journal:  West J Emerg Med       Date:  2018-04-05
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.