Literature DB >> 16483810

Multiexponential attenuation of the CPMG spin echoes due to a geometrical confinement.

D S Grebenkov1.   

Abstract

The CPMG multi-echo technique is often used to investigate the translational motion of diffusing nuclei in a confining medium. Henceforth, periodically repeated RF pulses with a diffusion-sensitizing gradient yield a formation of spin echoes of gradually decreasing amplitudes. The parameters of their exponential fits may characterize the structure of porous materials or biological tissue. In this paper, a multiexponential character of the CPMG measurements is rigorously demonstrated, once a geometrical confinement is present. Based on the multiple propagator approach, we derived a spectral representation for the echo amplitudes under external magnetic field of an arbitrary gradient profile. The multiple relaxation times and their spectral weights were found in a general form. The study of simple restrictive media allowed to obtain a quantitative condition under which the multiexponential attenuation is reduced to a monoexponential one.

Entities:  

Year:  2006        PMID: 16483810     DOI: 10.1016/j.jmr.2006.01.014

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  1 in total

1.  Fractional Order Analysis of Sephadex Gel Structures: NMR Measurements Reflecting Anomalous Diffusion.

Authors:  Richard L Magin; Belinda S Akpa; Thomas Neuberger; Andrew G Webb
Journal:  Commun Nonlinear Sci Numer Simul       Date:  2011-12-01       Impact factor: 4.260

  1 in total