DAVID--a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques.

B Poppe1, C Thieke, D Beyer, R Kollhoff, A Djouguela, A Rühmann, K C Willborn, D Harder.   

Abstract

Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while the patient is treated. The DAVID system is a flat, multi-wire transmission-type ionization chamber, placed in the accessory holder of the linear accelerator and constructed from translucent materials in order not to interfere with the light field. Each detection wire of the chamber is positioned exactly in the projection line of a MLC leaf pair, and the signal of each wire is proportional to the line integral of the ionization density along this wire. Thereby, each measurement channel essentially presents the line integral of the ionization density over the opening width of the associated leaf pair. The sum of all wire signals is a measure of the dose-area product of the transmitted photon beam and of the total radiant energy administered to the patient. After the dosimetric verification of an IMRT plan, the values measured by the DAVID system are stored as reference values. During daily treatment the signals are re-measured and compared to the reference values. A warning is output if there is a deviation beyond a threshold. The error detection capability is a leaf position error of less than 1 mm for an isocentric 1 cm x 1 cm field, and of 1 mm for an isocentric 20 cm x 20 cm field.

Entities:  

Mesh:

Year:  2006        PMID: 16481690     DOI: 10.1088/0031-9155/51/5/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Feasibility of a remote, automated daily delivery verification of volumetric-modulated arc therapy treatments using a commercial record and verify system.

Authors:  Jonas D Fontenot
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

2.  Consistency and reproducibility of the VMAT plan delivery using three independent validation methods.

Authors:  Varatharaj Chandraraj; Sotirios Stathakis; Ravikumar Manickam; Carlos Esquivel; Sanjay S Supe; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2010-11-16       Impact factor: 2.102

3.  Sensitivity Analysis of the Integral Quality Monitoring System® Using Monte Carlo Simulation.

Authors:  Oluwaseyi M Oderinde; F C P du Plessis
Journal:  Comput Math Methods Med       Date:  2017-08-27       Impact factor: 2.238

4.  A new transmission methodology for quality assurance in radiotherapy based on radiochromic film measurements.

Authors:  Leonardo L do Amaral; Harley F de Oliveira; Juliana F Pavoni; Franciso Sampaio; Thomaz Ghillardi Netto
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

5.  Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.

Authors:  David Hoffman; Eunah Chung; Clayton Hess; Robin Stern; Stanley Benedict
Journal:  J Appl Clin Med Phys       Date:  2016-11-29       Impact factor: 2.102

6.  Beam perturbation characteristics of a 2D transmission silicon diode array, Magic Plate.

Authors:  Ziyad A Alrowaili; Michael L F Lerch; Marco Petasecca; Martin G Carolan; Peter E Metcalfe; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

7.  Diode-based transmission detector for IMRT delivery monitoring: a validation study.

Authors:  Taoran Li; Q Jackie Wu; Thomas Matzen; Fang-Fang Yin; Jennifer C O'Daniel
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

8.  Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system.

Authors:  Gulay Karagoz; Faruk Zorlu; Mete Yeginer; Demet Yildiz; Gokhan Ozyigit
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

9.  A simple model for predicting the signal for a head-mounted transmission chamber system, allowing IMRT in-vivo dosimetry without pretreatment linac time.

Authors:  Daniel Johnson; Steven J Weston; Vivian P Cosgrove; David I Thwaites
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

10.  A systematic evaluation of the error detection abilities of a new diode transmission detector.

Authors:  Vikren Sarkar; Adam Paxton; Jeremy Kunz; Martin Szegedi; Geoff Nelson; Prema Rassiah-Szegedi; Hui Zhao; Y Jessica Huang; Frances Su; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2019-08-05       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.