Literature DB >> 16478111

Comparison of atmospheric pressure photoionization, atmospheric pressure chemical ionization, and electrospray ionization mass spectrometry for analysis of lipids.

Sheng-Suan Cai1, Jack A Syage.   

Abstract

In this work, we compare the quantitative accuracy and sensitivity of analyzing lipids by atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) LC/MS. The target analytes include free fatty acids and their esters, monoglyceride, diglyceride, and triglyceride. The results demonstrate the benefits of using LC/APPI-MS for lipid analysis. Analyses were performed on a Waters ZQ LC/MS. Normal-phase solvent systems were used due to low solubility of these compounds in aqueous reversed-phase solvent systems. By comparison, APPI offers lower detection limits, generally highest signal intensities, and the highest S/N ratio. APPI is 2-4 times more sensitive than APCI and much more sensitive than ESI without mobile-phase modifiers. APPI and APCI offer comparable linear range (i.e., 4-5 decades). ESI sensitivity is dramatically enhanced by use of mobile phase modifiers (i.e., ammonium formate or sodium acetate); however, these ESI adduct signals are less stable and either are nonlinear or have dramatically reduced linear ranges. Analysis of fish oils by APPI shows significantly enhanced target analyte intensities in comparison with APCI and ESI.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16478111     DOI: 10.1021/ac0515834

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2 , vitamin D3 , 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3.

Authors:  Jiri Adamec; Amber Jannasch; Jianjie Huang; Emily Hohman; James C Fleet; Munro Peacock; Mario G Ferruzzi; Berdine Martin; Connie M Weaver
Journal:  J Sep Sci       Date:  2010-11-16       Impact factor: 3.645

2.  APPI-MS: effects of mobile phases and VUV lamps on the detection of PAH compounds.

Authors:  Luke Chandler Short; Sheng-Suan Cai; Jack A Syage
Journal:  J Am Soc Mass Spectrom       Date:  2006-12-22       Impact factor: 3.109

Review 3.  Applications of mass spectrometry for cellular lipid analysis.

Authors:  Chunyan Wang; Miao Wang; Xianlin Han
Journal:  Mol Biosyst       Date:  2015-01-19

4.  Mapping the regioisomeric distribution of fatty acids in triacylglycerols by hybrid mass spectrometry.

Authors:  Kornél Nagy; Laurence Sandoz; Frédéric Destaillats; Olivier Schafer
Journal:  J Lipid Res       Date:  2012-10-23       Impact factor: 5.922

Review 5.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

6.  Atmospheric pressure photoionization mass spectrometry of polyisobutylene derivatives.

Authors:  Sándor Kéki; János Török; Lajos Nagy; Miklós Zsuga
Journal:  J Am Soc Mass Spectrom       Date:  2008-02-23       Impact factor: 3.109

7.  Global analysis of retina lipids by complementary precursor ion and neutral loss mode tandem mass spectrometry.

Authors:  Julia V Busik; Gavin E Reid; Todd A Lydic
Journal:  Methods Mol Biol       Date:  2009

8.  High-precision frequency measurements: indispensable tools at the core of the molecular-level analysis of complex systems.

Authors:  N Hertkorn; C Ruecker; M Meringer; R Gugisch; M Frommberger; E M Perdue; M Witt; P Schmitt-Kopplin
Journal:  Anal Bioanal Chem       Date:  2007-10-09       Impact factor: 4.142

9.  Dopant-assisted atmospheric pressure photoionization mass spectrometry of polyisobutylene derivatives initiated by mono- and bifunctional initiators.

Authors:  Lajos Nagy; Viktória Pálfi; Mijid Narmandakh; Akos Kuki; Andrea Nyíri; Béla Iván; Miklós Zsuga; Sándor Kéki
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-12       Impact factor: 3.109

10.  Ionization mechanism of negative ion-direct analysis in real time: a comparative study with negative ion-atmospheric pressure photoionization.

Authors:  Liguo Song; Andrew B Dykstra; Huifang Yao; John E Bartmess
Journal:  J Am Soc Mass Spectrom       Date:  2008-09-23       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.