Literature DB >> 16477417

Influence of infusion flow rates on central venous pressure measurements through multi-lumen central venous catheters in intensive care.

Karim Lakhal1, Martine Ferrandière, François Lagarrigue, Colette Mercier, Jacques Fusciardi, Marc Laffon.   

Abstract

OBJECTIVE: To study the influence on central venous pressure (CVP), measured at the distal port, of crystalloid infusions administered through the proximal port(s) of a central venous multi-lumen catheter. PATIENTS: Thirty-one intensive care patients.
INTERVENTIONS: CVP was measured at the distal port of a multi-lumen catheter inserted in the subclavian or internal jugular vein. Using the proximal port(s), saline (0.9%) was infused at rates varying from 2 ml/h to 14,340 ml/h.
RESULTS: CVP measured before the infusion and during infusion (after 30 s to 1 min) were not significantly different. Positive pressure ventilation with PEEP (5.6 +/- 2.5 cmH(2)O) and/or norepinephrine infusion (0.25 +/- 0.21 microg kg(-1) min(-1)) did not produce any significant change in CVP during infusion.
CONCLUSION: The administration of crystalloids at different flow rates through the proximal port(s) of a multi-lumen catheter placed in the superior vena cava does not affect CVP measurement at the distal port, even in mechanically ventilated patients or patients receiving vasopressors.

Entities:  

Mesh:

Year:  2006        PMID: 16477417     DOI: 10.1007/s00134-005-0049-6

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  14 in total

1.  Early goal-directed therapy in the treatment of severe sepsis and septic shock.

Authors:  E Rivers; B Nguyen; S Havstad; J Ressler; A Muzzin; B Knoblich; E Peterson; M Tomlanovich
Journal:  N Engl J Med       Date:  2001-11-08       Impact factor: 91.245

2.  Pressure-volume curves of the arterial and venous systems in live dogs.

Authors:  A C GUYTON; G G ARMSTRONG; P L CHIPLEY
Journal:  Am J Physiol       Date:  1956-02

3.  Venous pressure and compliance of the peripheral capacitance vessels.

Authors:  M Kato; S Saiki; T Y Ogino; T Suzuki; A Kojima; T Koeda; T Kimura
Journal:  Angiology       Date:  1976-12       Impact factor: 3.619

4.  How to use central venous pressure measurements.

Authors:  Sheldon Magder
Journal:  Curr Opin Crit Care       Date:  2005-06       Impact factor: 3.687

5.  Effects of PEEP on systemic venous capacitance.

Authors:  B Lambermont; O Detry; V D'Orio; J O Defraigne; A Fossion; P Gerard; R Marcelle; R Limet
Journal:  Arch Physiol Biochem       Date:  1998-08       Impact factor: 4.076

6.  More respect for the CVP.

Authors:  S Magder
Journal:  Intensive Care Med       Date:  1998-07       Impact factor: 17.440

7.  Effective compliance of the total vascular bed and the intrathoracic compartment derived from changes in central venous pressure induced by volume changes in man.

Authors:  M Echt; J Düweling; O H Gauer; L Lange
Journal:  Circ Res       Date:  1974-01       Impact factor: 17.367

8.  Maximum infusion rates and CVP accuracy during high-flow delivery through multilumen catheters.

Authors:  S Ikeda; J F Schweiss
Journal:  Crit Care Med       Date:  1985-07       Impact factor: 7.598

9.  Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock.

Authors:  R Phillip Dellinger; Jean M Carlet; Henry Masur; Herwig Gerlach; Thierry Calandra; Jonathan Cohen; Juan Gea-Banacloche; Didier Keh; John C Marshall; Margaret M Parker; Graham Ramsay; Janice L Zimmerman; Jean-Louis Vincent; M M Levy
Journal:  Intensive Care Med       Date:  2004-03-03       Impact factor: 17.440

10.  Comparison of intrathoracic and intra-abdominal measurements of central venous pressure.

Authors:  G M Joynt; C D Gomersall; T A Buckley; T E Oh; R J Young; R C Freebairn
Journal:  Lancet       Date:  1996-04-27       Impact factor: 79.321

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.