Literature DB >> 16477411

Saline volume in transvesical intra-abdominal pressure measurement: enough is enough.

J De Waele1, P Pletinckx, S Blot, E Hoste.   

Abstract

OBJECTIVE: The objective was to determine the minimum volume of instillation fluid for intra-abdominal pressure (IAP) measurement, and to evaluate the effect of instillation volume on transvesically measured IAP.
DESIGN: Prospective cohort study
SETTING: Twenty-two-bed surgical ICU of the Ghent University Hospital. PATIENTS AND PARTICIPANTS: Twenty patients at risk of intra-abdominal hypertension (IAH).
INTERVENTIONS: Transvesical IAP measurement using volumes from 10 to 100 ml. Minimal volume at which an IAP was measured was recorded (IAP(min)), as well as IAP at 50 and 100 ml of instillation volume (IAP(50) and IAP(100)). The percentage difference for IAP(50) and IAP(100) was calculated. MEASUREMENTS AND
RESULTS: The minimal volume for IAP measurement was 10 ml in all patients. Mean IAP(min) was 12.8 mmHg (+/- 4.9), mean IAP(50 )15 mmHg (+/- 4.5) and mean IAP(100) 17.1mmHg (+/- 4.7). The mean percentage difference for IAP(50) was 21% (+/- 17%), and 40% (+/-29%) for IAP(100.) Twelve patients were categorised as suffering from IAH when 10 ml of saline was used for IAP measurement, increasing to 15 and 17 patients respectively when using 50 and 100 ml. In patients with IAH, there was a significant correlation between the duration of bladder drainage and percentage difference for IAP(100) (Pearson correlation coefficient 0.60, p = 0.03).
CONCLUSIONS: Using 50 or 100 ml of saline for IAP measurement in critically ill patients results in higher IAP values compared with the use of 10 ml, and possibly, in overestimation of the incidence of intra-abdominal hypertension.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16477411     DOI: 10.1007/s00134-005-0062-9

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  14 in total

1.  Estimation of intra-abdominal pressure by bladder pressure measurement: validity and methodology.

Authors:  M A Fusco; R S Martin; M C Chang
Journal:  J Trauma       Date:  2001-02

2.  Can we use the bladder to estimate intra-abdominal pressure?

Authors:  S Johna
Journal:  J Trauma       Date:  2001-12

3.  Continuous intra-abdominal pressure measurement technique.

Authors:  Zsolt Balogh; Felicity Jones; Scott D'Amours; Michael Parr; Michael Sugrue
Journal:  Am J Surg       Date:  2004-12       Impact factor: 2.565

4.  Intraabdominal pressure: a revised method for measurement.

Authors:  M L Cheatham; K Safcsak
Journal:  J Am Coll Surg       Date:  1998-05       Impact factor: 6.113

5.  Determination of intra-abdominal pressure using a transurethral bladder catheter: clinical validation of the technique.

Authors:  T J Iberti; C E Lieber; E Benjamin
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

6.  Bladder hypocompliance in the spinal cord injury population.

Authors:  R H Hackler; M K Hall; T A Zampieri
Journal:  J Urol       Date:  1989-06       Impact factor: 7.450

7.  The measurement of intra-abdominal pressure as a criterion for abdominal re-exploration.

Authors:  I L Kron; P K Harman; S P Nolan
Journal:  Ann Surg       Date:  1984-01       Impact factor: 12.969

Review 8.  Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal.

Authors:  Manu L N G Malbrain
Journal:  Intensive Care Med       Date:  2004-01-17       Impact factor: 17.440

9.  Prevalence of intra-abdominal hypertension in critically ill patients: a multicentre epidemiological study.

Authors:  Manu L N G Malbrain; Davide Chiumello; Paolo Pelosi; Alexander Wilmer; Nicola Brienza; Vincenzo Malcangi; David Bihari; Richard Innes; Jonathan Cohen; Pierre Singer; Andre Japiassu; Elizabeth Kurtop; Bart L De Keulenaer; Ronny Daelemans; Monica Del Turco; P Cosimini; Marco Ranieri; Luc Jacquet; Pierre-François Laterre; Luciano Gattinoni
Journal:  Intensive Care Med       Date:  2004-02-03       Impact factor: 17.440

10.  Abdominal compartment syndrome: does intra-cystic pressure reflect actual intra-abdominal pressure? A prospective study in surgical patients.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

View more
  27 in total

1.  Validation of the urine column measurement as an estimation of the intra-abdominal pressure.

Authors:  Herjan van der Steeg; Jesse P van Akkeren; Saskia Houterman; Rudi M H Roumen
Journal:  Intensive Care Med       Date:  2009-01-06       Impact factor: 17.440

2.  AIDS is coming to your ICU: be prepared for acute bowel injury and acute intestinal distress syndrome...

Authors:  Manu L N G Malbrain; Inneke De Laet
Journal:  Intensive Care Med       Date:  2008-05-01       Impact factor: 17.440

3.  Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations.

Authors:  Michael L Cheatham; Manu L N G Malbrain; Andrew Kirkpatrick; Michael Sugrue; Michael Parr; Jan De Waele; Zsolt Balogh; Ari Leppäniemi; Claudia Olvera; Rao Ivatury; Scott D'Amours; Julia Wendon; Ken Hillman; Alexander Wilmer
Journal:  Intensive Care Med       Date:  2007-03-22       Impact factor: 17.440

4.  Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions.

Authors:  Manu L N G Malbrain; Michael L Cheatham; Andrew Kirkpatrick; Michael Sugrue; Michael Parr; Jan De Waele; Zsolt Balogh; Ari Leppäniemi; Claudia Olvera; Rao Ivatury; Scott D'Amours; Julia Wendon; Ken Hillman; Kenth Johansson; Karel Kolkman; Alexander Wilmer
Journal:  Intensive Care Med       Date:  2006-09-12       Impact factor: 17.440

Review 5.  Current insights in intra-abdominal hypertension and abdominal compartment syndrome: open the abdomen and keep it open!

Authors:  Inneke E De Laet; Mariska Ravyts; Wesley Vidts; Jody Valk; Jan J De Waele; Manu L N G Malbrain
Journal:  Langenbecks Arch Surg       Date:  2008-06-17       Impact factor: 3.445

6.  The effect of different reference transducer positions on intra-abdominal pressure measurement: a multicenter analysis.

Authors:  Jan J De Waele; Inneke De Laet; Bart De Keulenaer; Sandy Widder; Andrew W Kirkpatrick; Adrian B Cresswell; Manu Malbrain; Zsolt Bodnar; Jorge H Mejia-Mantilla; Richard Reis; Michael Parr; Robert Schulze; Sonia Compano; Michael Cheatham
Journal:  Intensive Care Med       Date:  2008-04-04       Impact factor: 17.440

7.  Intraabdominal hypertension and the abdominal compartment syndrome in burn patients.

Authors:  Andrew W Kirkpatrick; Chad G Ball; Duncan Nickerson; Scott K D'Amours
Journal:  World J Surg       Date:  2009-06       Impact factor: 3.352

8.  Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note.

Authors:  Jens Otto; Daniel Kaemmer; Marcel Binnebösel; Marc Jansen; Rolf Dembinski; Volker Schumpelick; Alexander Schachtrupp
Journal:  BMC Surg       Date:  2009-04-21       Impact factor: 2.102

9.  In vitro validation of a novel method for continuous intra-abdominal pressure monitoring.

Authors:  Manu L N G Malbrain; Inneke De laet; Dries Viaene; Karen Schoonheydt; Hilde Dits
Journal:  Intensive Care Med       Date:  2007-12-13       Impact factor: 17.440

10.  Intra-abdominal pressure alterations after large pancreatic pseudocyst transcutaneous drainage.

Authors:  Theodossis S Papavramidis; Vassilis Duros; Antonis Michalopoulos; Vassilis N Papadopoulos; Daniel Paramythiotis; Nick Harlaftis
Journal:  BMC Gastroenterol       Date:  2009-06-06       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.