Literature DB >> 16477016

Directly observed reversible shape changes and hemoglobin stratification during centrifugation of human and Amphiuma red blood cells.

Joseph F Hoffman1, Shinya Inoué.   

Abstract

This paper describes changes that occur in human and Amphiuma red blood cells observed during centrifugation with a special microscope. Dilute suspensions of cells were layered, in a centrifuge chamber, above an osmotically matched dense solution, containing Nycodenz, Ficoll, or Percoll (Pharmacia) that formed a density gradient that allowed the cells to slowly settle to an equilibrium position. Biconcave human red blood cells moved downward at low forces with minimum wobble. The cells oriented vertically when the force field was increased and Hb sedimented as the lower part of each cell became bulged and assumed a "bag-like" shape. The upper centripetal portion of the cell became thinner and remained biconcave. These changes occurred rapidly and were completely reversible upon lowering the centrifugal force. Bag-shaped cells, upon touching red cells in rouleau, immediately reverted to biconcave disks as they flipped onto a stack. Amphiuma red cells displayed a different type of reversible stratification and deformation at high force fields. Here the cells became stretched, with the nucleus now moving centrifugally, the Hb moving centripetally, and the bottom of the cells becoming thinner and clear. Nevertheless, the distribution of the marginal bands at the cells' rim was unchanged. We conclude that centrifugation, per se, while changing a red cell's shape and the distribution of its intracellular constituents, does so in a completely reversible manner. Centrifugation of red cells harboring altered or missing structural elements could provide information on shape determinants that are still unexplained.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16477016      PMCID: PMC1413809          DOI: 10.1073/pnas.0510884103

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  22 in total

Review 1.  Centrifuge polarizing microscope. I. Rationale, design and instrument performance.

Authors:  S Inoué; R A Knudson; M Goda; K Suzuki; C Nagano; N Okada; H Takahashi; K Ichie; M Iida; K Yamanaka
Journal:  J Microsc       Date:  2001-03       Impact factor: 1.758

2.  Questions for red blood cell physiologists to ponder in this millenium.

Authors:  J F Hoffman
Journal:  Blood Cells Mol Dis       Date:  2001 Jan-Feb       Impact factor: 3.039

3.  The hydrodynamic radii of macromolecules and their effect on red blood cell aggregation.

Authors:  J K Armstrong; R B Wenby; H J Meiselman; T C Fisher
Journal:  Biophys J       Date:  2004-09-10       Impact factor: 4.033

4.  Stratification of the erythrocytes of man by ultracentrifuging.

Authors:  H W BEAMS
Journal:  Proc Soc Exp Biol Med       Date:  1947-11

5.  Deformation of human erythrocytes in a centrifugal field.

Authors:  W D Corry; H J Meiselman
Journal:  Biophys J       Date:  1978-01       Impact factor: 4.033

6.  Centrifugal packing of erythrocytes hardened with acetaldehyde.

Authors:  S Chien; R J Dellenback; S Usami; G V Seaman; M I Gregersen
Journal:  Proc Soc Exp Biol Med       Date:  1968-04

7.  Deformation of red blood cells in capillaries.

Authors:  R Skalak; P I Branemark
Journal:  Science       Date:  1969-05-09       Impact factor: 47.728

8.  The red cell as a fluid droplet: tank tread-like motion of the human erythrocyte membrane in shear flow.

Authors:  T M Fischer; M Stöhr-Lissen; H Schmid-Schönbein
Journal:  Science       Date:  1978-11-24       Impact factor: 47.728

9.  Red blood cell rouleaux formation in dextran solution: dependence on polymer conformation.

Authors:  G Barshtein; I Tamir; S Yedgar
Journal:  Eur Biophys J       Date:  1998       Impact factor: 1.733

10.  Ionic and osmotic equilibria of human red blood cells treated with nystatin.

Authors:  J C Freedman; J F Hoffman
Journal:  J Gen Physiol       Date:  1979-08       Impact factor: 4.086

View more
  1 in total

1.  Calibration of a prototype NIRS oximeter against two commercial devices on a blood-lipid phantom.

Authors:  Simon Hyttel-Sorensen; Stefan Kleiser; Martin Wolf; Gorm Greisen
Journal:  Biomed Opt Express       Date:  2013-08-14       Impact factor: 3.732

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.