Literature DB >> 16475608

Modified functional impression technique for complete dentures.

Alexandre Malachias1, Helena de Freitas Oliveira Paranhos, Cláudia Helena Lovato da Silva, Valdir Antônio Muglia, Carla Moreto.   

Abstract

This report describes the use of a removable acrylic resin tray handle that can be easily attached to custom impression trays to produce an improved peripheral sealing zone. This device can be indicated to develop functional impressions for complete dentures using the patient-conducted muscular motion technique. In upper trays, the handle is fixed in the midline with acrylic resin, while in lower trays the centrally positioned handle is removed before border molding. This removable handle allows patient's suction and free tongue movements. Final impression is carried out in two stages: peripheral sealing (low fusion compound) and recording of the main supporting region of the denture (zinc oxide and eugenol paste). All border records are obtained from the patient's own movements (handle suction and tongue motion). The removable handle is simple to use, is reusable, can be adapted to any individual acrylic resin trays and allows accurate registration of the peripheral sealing zone (border tissues).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16475608     DOI: 10.1590/s0103-64402005000200009

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  5 in total

1.  A systematic review of impression technique for conventional complete denture.

Authors:  Shubha Rao; R Chowdhary; S Mahoorkar
Journal:  J Indian Prosthodont Soc       Date:  2010-12-17

Review 2.  Functional Impressions in Complete Denture and Overdenture Treatment.

Authors:  Hrvoje Kršek; Nikša Dulčić
Journal:  Acta Stomatol Croat       Date:  2015-03

3.  Clinical evaluation of tissue stops on 3D-printed custom trays.

Authors:  Kehui Deng; Hu Chen; Rong Li; Linlin Li; Yong Wang; Yongsheng Zhou; Yuchun Sun
Journal:  Sci Rep       Date:  2019-02-12       Impact factor: 4.379

4.  Clinical management of highly resorbed mandibular ridge without fibrous tissue.

Authors:  Veeramalai N Devaki; Paramasivam Manonmani; Kandasamy Balu; Ramraj Jayabalan Aravind
Journal:  J Pharm Bioallied Sci       Date:  2012-08

5.  Oral Health Related Quality of Life and Prosthetic Status among Institutionalized Elderly from the Bucharest Area: A Pilot Study.

Authors:  Laura Iosif; Cristina Teodora Preoteasa; Elena Preoteasa; Ana Ispas; Radu Ilinca; Cǎtǎlina Murariu-Mǎgureanu; Oana Elena Amza
Journal:  Int J Environ Res Public Health       Date:  2021-06-21       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.