Literature DB >> 16471801

Fabrication of electroactive layer-by-layer films of myoglobin with gold nanoparticles of different sizes.

Hong Zhang1, Haiyun Lu, Naifei Hu.   

Abstract

Alternate adsorption of oppositely charged myoglobin (Mb) and gold nanoparticles with different sizes were used to assemble {Au/Mb}n layer-by-layer films on solid surfaces by electrostatic interaction between them. The direct electrochemistry of Mb was realized in {Au/Mb}n films at pyrolytic graphite (PG) electrodes, showing a pair of well-defined, nearly reversible cyclic voltammetry (CV) peaks for the Mb heme FeIII/FeII redox couple. Quartz crystal microbalance (QCM), electrochemical impedance spectroscopy (EIS), and CV were used to monitor or confirm the growth of the films. Compared with other Mb layer-by-layer films with nonconductive nanoparticles or polyions, {Au/Mb}n films showed much improved properties, such as smaller electron-transfer resistance (Rct) measured by EIS with Fe(CN)3-/4- redox probe, higher maximum surface concentration of electroactive Mb (Gamma*max), and better electrocatalytic activity toward reduction of O2 and H2O2, mainly because of the good conductivity of Au nanoparticles. Because of the high biocompatibility of Au nanoparticles, adsorbed Mb in the films retained its near native structure and biocatalytic activity. The size effect of Au nanoparticles on the electrochemical and electrocatalytic activity of Mb in {Au/Mb}n films was investigated, demonstrating that the {Au/Mb}n films assembled with smaller-sized Au nanoparticles have smaller Rct, higher Gamma*max, and better biocatalytic reactivity than those with larger size.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16471801     DOI: 10.1021/jp055301f

Source DB:  PubMed          Journal:  J Phys Chem B        ISSN: 1520-5207            Impact factor:   2.991


  6 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

2.  Protecting peroxidase activity of multilayer enzyme-polyion films using outer catalase layers.

Authors:  Haiyun Lu; James F Rusling; Naifei Hu
Journal:  J Phys Chem B       Date:  2007-12-05       Impact factor: 2.991

3.  Ultrasensitive immunosensor for cancer biomarker proteins using gold nanoparticle film electrodes and multienzyme-particle amplification.

Authors:  Vigneshwaran Mani; Bhaskara V Chikkaveeraiah; Vyomesh Patel; J Silvio Gutkind; James F Rusling
Journal:  ACS Nano       Date:  2009-03-24       Impact factor: 15.881

4.  Designing nanomaterial-enhanced electrochemical immunosensors for cancer biomarker proteins.

Authors:  James F Rusling; Gregory Sotzing; Fotios Papadimitrakopoulosa
Journal:  Bioelectrochemistry       Date:  2009-04-05       Impact factor: 5.373

5.  Long Distance Electron Transfer Across >100 nm Thick Au Nanoparticle/Polyion Films to a Surface Redox Protein.

Authors:  Hongmei Chai; Hongyun Liu; Xihong Guo; Dong Zheng; Yasemin Kutes; Bryan D Huey; James F Rusling; Naifei Hu
Journal:  Electroanalysis       Date:  2012-05-01       Impact factor: 3.223

6.  Immobilization of myoglobin on Au nanoparticle-decorated carbon nanotube/polytyramine composite as a mediator-free H2O2 and nitrite biosensor.

Authors:  A T Ezhil Vilian; Vediyappan Veeramani; Shen-Ming Chen; Rajesh Madhu; Cheol Hwan Kwak; Yun Suk Huh; Young-Kyu Han
Journal:  Sci Rep       Date:  2015-12-17       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.