Literature DB >> 16470830

Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution.

Hyung-Soo Ahn1, Myong-Jin Kim, Hyo-Joung Seol, Jung-Hyun Lee, Hyung-Il Kim, Yong Hoon Kwon.   

Abstract

Orthodontic arch wires can confront diverse pH and temperature conditions in the oral cavity after replacement. The current study evaluated the effect of pH and temperature on orthodontic NiTi arch wires after immersion in an acidic fluoride solution. The acetic acid added for the adjustment of pH forms hydrofluoric acid (HF). More HF was formed in a solution of lower pH with higher temperature than that of the higher pH with lower temperature. Within the same pH value, the temperature of the solution affected the concentration of HF. Each as-received wire exhibited quite different microhardness values. The reduction of microhardness, 1.2-5.7%, occurred after immersion. Within the same product, however, the pH and temperature had minor influence on the reduction. The volumetric weight change, concentration of the released elements, and surface morphology were influenced by pH and temperature. At pH 3.5 of 60 degrees C solution, the greatest weight loss, release of elements, and corrosion of surface occurred from the wires. At pH 6, on the other hand, no such loss or release occurred regardless of temperature. At 5 degrees C solution, the surface exhibited minor corrosion regardless of pH value.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16470830     DOI: 10.1002/jbm.b.30505

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  6 in total

1.  The corrosion resistance of composite arch wire laser-welded by NiTi shape memory alloy and stainless steel wires with Cu interlayer in artificial saliva with protein.

Authors:  Chao Zhang; Xinhua Sun; Xu Hou; Hongmei Li; Daqian Sun
Journal:  Int J Med Sci       Date:  2013-06-21       Impact factor: 3.738

2.  An in vitro assessment of the mechanical characteristics of nickel-titanium orthodontic wires in Fluoride solutions with different acidities.

Authors:  Shiva Alavi; Sara Barooti; Ali Borzabadi-Farahani
Journal:  J Orthod Sci       Date:  2015 Apr-Jun

3.  Nickel Ion Release from Three Types of Nickel-titanium-based Orthodontic Archwires in the As-received State and After Oral Simulation.

Authors:  Barat Ali Ramazanzadeh; Farzaneh Ahrari; Berahman Sabzevari; Samaneh Habibi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-06-11

4.  Effect of pH on in vitro biocompatibility of orthodontic miniscrew implants.

Authors:  Angela Galeotti; Roberto Uomo; Gianrico Spagnuolo; Sergio Paduano; Roberta Cimino; Rosa Valletta; Vincenzo D'Antò
Journal:  Prog Orthod       Date:  2013-07-01       Impact factor: 2.750

5.  Effect of antiasthmatic medication on the surface roughness and color stability of dental restorative materials.

Authors:  Elif Aydogan Ayaz; Bora Bagis; Sedanur Turgut
Journal:  Med Princ Pract       Date:  2013-08-29       Impact factor: 1.927

Review 6.  Is titanium alloy Ti-6Al-4 V cytotoxic to gingival fibroblasts-A systematic review.

Authors:  Jonathan Willis; Siwei Li; St John Crean; Fadi N Barrak
Journal:  Clin Exp Dent Res       Date:  2021-05-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.