Literature DB >> 16470723

Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry.

F Calbiani1, M Careri, L Elviri, A Mangia, I Zagnoni.   

Abstract

Liquid chromatography (LC) with high-resolution mass spectrometry (HRMS) represents a powerful technique for the identification and/or confirmation of small molecules, i.e. drugs, metabolites or contaminants, in different matrices. However, reliability of analyte identification by HRMS is being challenged by the uncertainty that affects the exact mass measurement. This parameter, characterized by accuracy and precision, is influenced by sample matrix and interferent compounds so that questions about how to develop and validate reliable LC-HRMS-based methods are being raised. Experimental approaches for studying the effects of various key factors influencing mass accuracy on low-molecular weight compounds (MW < 150 Da) when using a quadrupole-time-of-flight (QTOF) mass analyzer were described. Biogenic amines in human plasma were considered for the purpose and the effects of peak shape, ion abundance, resolution and data processing on accurate mass measurements of the analytes were evaluated. In addition, the influence of the matrix on the uncertainty associated with their identification and quantitation is discussed. A critical evaluation on the calculation of the limits of detection was carried out, considering the uncertainty associated with exact mass measurement of HRMS-based methods. The minimum concentration level of the analytes that was able to provide a statistical error lower than 5 ppm in terms of precision was 10 times higher than those calculated with S/N = 3, thus suggesting the importance of considering both components of exact mass measurement uncertainty in the evaluation of the limit of detection.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16470723     DOI: 10.1002/jms.984

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  4 in total

1.  Full-scan accurate mass selectivity of ultra-performance liquid chromatography combined with time-of-flight and orbitrap mass spectrometry in hormone and veterinary drug residue analysis.

Authors:  E van der Heeft; Y J C Bolck; B Beumer; A W J M Nijrolder; A A M Stolker; M W F Nielen
Journal:  J Am Soc Mass Spectrom       Date:  2008-11-17       Impact factor: 3.109

2.  Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters: a case study of the Henares River (Madrid, Spain).

Authors:  Andrés Pérez-Parada; María del Mar Gómez-Ramos; María Jesús Martínez Bueno; Samanta Uclés; Ana Uclés; Amadeo R Fernández-Alba
Journal:  Environ Sci Pollut Res Int       Date:  2011-08-07       Impact factor: 4.223

3.  Metabolome searcher: a high throughput tool for metabolite identification and metabolic pathway mapping directly from mass spectrometry and using genome restriction.

Authors:  A Ranjitha Dhanasekaran; Jon L Pearson; Balasubramanian Ganesan; Bart C Weimer
Journal:  BMC Bioinformatics       Date:  2015-02-25       Impact factor: 3.169

4.  Comprehensive screening and quantification of veterinary drugs in milk using UPLC-ToF-MS.

Authors:  A A M Stolker; P Rutgers; E Oosterink; J J P Lasaroms; R J B Peters; J A van Rhijn; M W F Nielen
Journal:  Anal Bioanal Chem       Date:  2008-05-20       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.