Literature DB >> 16470258

Comparison of 24 h averaged VOC monitoring results for residential indoor and outdoor air using Carbopack X-filled diffusive samplers and active sampling--a pilot study.

William A McClenny1, Henry H Jacumin, Karen D Oliver, E Hunter Daughtrey, Donald A Whitaker.   

Abstract

Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16470258     DOI: 10.1039/b507850d

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  3 in total

1.  Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes.

Authors:  Karen D Oliver; Tamira A Cousett; Donald A Whitaker; Luther A Smith; Shaibal Mukerjee; Casson Stallings; Eben D Thoma; Lillian Alston; Maribel Colon; Tai Wu; Stacy Henkle
Journal:  Atmos Environ (1994)       Date:  2017-08       Impact factor: 4.798

2.  Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Sibel Mentese; Karen D Oliver; Donald A Whitaker; Kenneth W Fent
Journal:  J Chromatogr A       Date:  2017-07-28       Impact factor: 4.759

3.  Elevated Indoor Volatile Organic Compound Exposure in the Niger Delta Region of Nigeria.

Authors:  Kalé Z Kponee; Jamaji C Nwanaji-Enwerem; Xianqiang Fu; Iyenemi I Kakulu; Marc G Weisskopf; Chunrong Jia
Journal:  Int J Environ Res Public Health       Date:  2018-09-06       Impact factor: 3.390

  3 in total