Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback.

Rajiv Chopra1, Jeff Wachsmuth, Mathieu Burtnyk, Masoom A Haider, Michael J Bronskill.   

Abstract

The feasibility of using MR thermometry for temperature feedback to control a transurethral ultrasound heating applicator with planar transducers was investigated. The sensitivity of a temperature-based feedback algorithm to spatial (control point area, slice thickness, angular alignment) and non-spatial (imaging time, temperature uncertainty) parameters was evaluated through numerical simulations. The angular alignment of the control point with the ultrasound beam was an important parameter affecting the average spatial error in heat delivery. The other spatial parameters were less influential, thus providing an opportunity to reduce spatial resolution for increased SNR in the MR imaging. The update time was the most important non-spatial parameter determining the performance of the control algorithm. Combined non-spatial and spatial parameters achieved acceptable performance with a voxel size of 3 mm x 3 mm, a 10 mm slice thickness and a 5 s update time. Temperature uncertainty of up to 2 degrees C had little effect on the performance of the control algorithm but did reduce the average error slightly due to a systematic, noise-induced overestimation of the boundary temperature. These simulations imply that MR thermometry performed on clinical 1.5 T imaging systems is of sufficient quality for use as thermal feedback for conformal prostate thermal therapy with transurethral ultrasound heating applicators incorporating planar transducers.

Mesh:

Year:  2006        PMID: 16467581     DOI: 10.1088/0031-9155/51/4/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

Review 1.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

2.  Considerations for theoretical modelling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control.

Authors:  Punit Prakash; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

3.  Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: in vivo evaluation under MR guidance.

Authors:  Adam M Kinsey; Chris J Diederich; Viola Rieke; William H Nau; Kim Butts Pauly; Donna Bouley; Graham Sommer
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  MR thermometry in the human prostate gland at 3.0T for transurethral ultrasound therapy.

Authors:  Elizabeth Ramsay; Charles Mougenot; Max Köhler; Michael Bronskill; Laurence Klotz; Masoom A Haider; Rajiv Chopra
Journal:  J Magn Reson Imaging       Date:  2013-02-25       Impact factor: 4.813

5.  Evaluation of Focal Ablation of Magnetic Resonance Imaging Defined Prostate Cancer Using Magnetic Resonance Imaging Controlled Transurethral Ultrasound Therapy with Prostatectomy as the Reference Standard.

Authors:  Elizabeth Ramsay; Charles Mougenot; Robert Staruch; Aaron Boyes; Mohammad Kazem; Michael Bronskill; Harry Foster; Linda Sugar; Masoom Haider; Laurence Klotz; Rajiv Chopra
Journal:  J Urol       Date:  2016-08-18       Impact factor: 7.450

6.  Online feedback focusing algorithm for hyperthermia cancer treatment.

Authors:  Kung-Shan Cheng; Vadim Stakhursky; Paul Stauffer; Mark Dewhirst; Shiva K Das
Journal:  Int J Hyperthermia       Date:  2007-11       Impact factor: 3.914

Review 7.  Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning.

Authors:  Punit Prakash; Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2013-06       Impact factor: 3.914

8.  Treatment of esophageal tumors using high intensity intraluminal ultrasound: first clinical results.

Authors:  David Melodelima; Frederic Prat; Jacques Fritsch; Yves Theillere; Dominique Cathignol
Journal:  J Transl Med       Date:  2008-06-05       Impact factor: 5.531