Literature DB >> 16464829

Interventional magnetic resonance imaging: an alternative to image guidance with ionising radiation.

M Bock1, R Umathum, S Zuehlsdorff, S Volz, C Fink, P Hallscheidt, H Zimmermann, W Nitz, W Semmler.   

Abstract

At present, interventional procedures, such as stent placement, are performed under X-ray image guidance. Unfortunately with X-ray imaging, both patient and interventionalist are exposed to ionising radiation. Furthermore, X-ray imaging is lacking soft tissue contrast and is not capable of true 3-D displays of either interventional device or tissue morphology. Magnetic resonance imaging (MRI) offers excellent soft tissue contrast, 3-D acquisition techniques, as well as rapid image acquisition and reconstruction. Despite these advantages, MR-guided interventions are challenging owing to the limited access to the patient, strong magnetic and radio-frequency fields that require special interventional devices, inferior image frame rates and spatial resolution, and high MRI scanner noise. For MR-guided intravascular interventions, where access to the target organ is achieved through catheters, dedicated hardware and automated image slice positioning techniques have been developed. We illustrate that MR-guided renal embolisations can be performed in closed-bore high-field MR scanners.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16464829     DOI: 10.1093/rpd/nci731

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Two eyes see more than one: double echo stereoscopic MRA for rapid 3D visualization of vascular structures.

Authors:  Alexander Brunner; Florian Maier; Axel Joachim Krafft; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2012-04-05       Impact factor: 2.310

2.  Preoperative assessment and follow-up of congenital abnormalities of the pulmonary arteries using CT and MRI.

Authors:  Sebastian Ley; Julia Zaporozhan; Raoul Arnold; Joachim Eichhorn; Jens-Peter Schenk; Herbert Ulmer; Karl-Friedrich Kreitner; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2006-06-24       Impact factor: 5.315

3.  Preclinical feasibility of a technology framework for MRI-guided iliac angioplasty.

Authors:  Martin A Rube; Fabiola Fernandez-Gutierrez; Benjamin F Cox; Andrew B Holbrook; J Graeme Houston; Richard D White; Helen McLeod; Mahsa Fatahi; Andreas Melzer
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-08-08       Impact factor: 2.924

4.  Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study.

Authors:  Vanessa Franziska Schmidt; Federica Arnone; Olaf Dietrich; Max Seidensticker; Marco Armbruster; Jens Ricke; Philipp Maximilian Kazmierczak
Journal:  Sci Rep       Date:  2021-11-25       Impact factor: 4.379

  4 in total