Literature DB >> 16463356

Oscillating steady states.

Klaus Scheffler1, Stefan Maderwald, Mark E Ladd, Oliver Bieri.   

Abstract

The signal formation and properties of steady-state free precession (SSFP) in combination with alternating RF pulse phases or alternating spin precession is analyzed. Simulations and experiments demonstrate that the amplitudes of SSFP echo paths are significantly influenced by application of alternating phases either via the exciting RF pulse or via some external mechanism producing alternating spin precession. The influence of alternating phases on echo amplitudes is different for different echo paths. The primary SSFP echo paths F(0) (-) and F(0) (+) exhibit a signal reduction whereas higher-order echoes F(-1) (-) and F(1) (+) show a signal increase upon application of oscillating phases. This behavior can be described using a simple perturbation theory applied to the frequency response profile of balanced SSFP combined with a final signal integration over one balanced SSFP band. The high sensitivity of SSFP echo amplitudes to alternating RF pulse phases or precession is exemplarily used to detect and visualize propagating transverse acoustic shear waves. Detection of flow or alternating currents are further possibilities to apply this unique feature of SSFP. Magn Reson Med, 2006. (c) 2006 Wiley-Liss, Inc.

Mesh:

Year:  2006        PMID: 16463356     DOI: 10.1002/mrm.20795

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Interleaved balanced SSFP imaging: artifact reduction using gradient waveform grouping.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

2.  Simultaneous Multi-VENC and Simultaneous Multi-Slice Phase Contrast Magnetic Resonance Imaging.

Authors:  Suhyung Park; Liyong Chen; Jennifer Townsend; Hyunyeol Lee; David A Feinberg
Journal:  IEEE Trans Med Imaging       Date:  2019-08-12       Impact factor: 10.048

3.  Oscillating steady-state imaging (OSSI): A novel method for functional MRI.

Authors:  Shouchang Guo; Douglas C Noll
Journal:  Magn Reson Med       Date:  2020-01-08       Impact factor: 4.668

4.  The central signal singularity phenomenon in balanced SSFP and its application to positive-contrast imaging.

Authors:  R Reeve Ingle; Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2011-10-24       Impact factor: 4.668

5.  Unipolar MR elastography: Theory, numerical analysis and implementation.

Authors:  Christian Guenthner; Sweta Sethi; Marian Troelstra; Robbert J H van Gorkum; Mareike Gastl; Ralph Sinkus; Sebastian Kozerke
Journal:  NMR Biomed       Date:  2019-10-30       Impact factor: 4.044

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.