Literature DB >> 16462561

Does fibular plating improve alignment after intramedullary nailing of distal metaphyseal tibia fractures?

Kenneth A Egol1, Russell Weisz, Rudi Hiebert, Nirmal C Tejwani, Kenneth J Koval, Roy W Sanders.   

Abstract

OBJECTIVE: Evaluate whether supplementary fibular fixation helped maintain axial alignment in distal metaphyseal tibia-fibula fractures treated by locked intramedullary nailing.
DESIGN: Retrospective chart and radiographic review.
SETTING: Three, level 1, trauma centers. PATIENTS: Distal metaphyseal tibia-fibula fractures were separated into 2 groups based on the presence of adjunctive fibular plating. Group 1 consisted of fractures treated with small fragment plate fixation of the fibula and intramedullary (IM) nailing of the tibia, whereas group 2 consisted of fractures treated with IM nailing of the tibia without fibular fixation. OUTCOME MEASURES: Malalignment of the tibial shaft was defined as 1) >5 degrees of varus/valgus angulation, or 2) >10 degrees anterior/posterior angulation. Measures of angulation were obtained from radiographs taken immediately after the surgery, a second time 3 months later, and at 6-month follow-up. Leg length and rotational deformity were not examined.
RESULTS: Seventy-two fractures were studied. In 25 cases, the associated fibula fracture was stabilized, and in 47 cases the associated fibula fracture was not stabilized. Cases were more likely to have the associated fibula fracture stabilized where the tibia fracture was very distal. In multivariate adjusted analysis, plating of the fibula fracture was significantly associated with maintenance of reduction 12 weeks or later after surgery (odds ratio = 0.03; P = 0.036). The use of 2 medial-lateral distal locking bolts also was protective against loss of reduction; however, this association was not statistically significant (odds ratio = 0.29; P = 0.275).
CONCLUSIONS: In this study, the proportion of fractures that lost alignment was smaller among those receiving stabilization of the fibula in conjunction with IM nailing compared with those receiving IM nailing alone. Adjunctive fibular stabilization was associated significantly with the ability to maintain fracture reduction beyond 12 weeks. At the present time, the authors recommend fibular plating whenever IM nailing is contemplated in the unstable distal tibia-fibular fracture.

Entities:  

Mesh:

Year:  2006        PMID: 16462561     DOI: 10.1097/01.bot.0000199118.61229.70

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  24 in total

1.  Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.

Authors:  David W Lowenberg; Malcolm R DeBaun; Anthony Behn; Alex Sox-Harris
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-05-04

2.  The healing stages of an intramedullary implanted tibia: A stress strain comparative analysis of the calcification process.

Authors:  Vincenzo Filardi
Journal:  J Orthop       Date:  2015-01-31

3.  Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients.

Authors:  Rafiq Bhat; Mubashir Maqbool Wani; Shakir Rashid; Nahida Akhter
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-20

4.  [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].

Authors:  R El Attal; M Hansen; R Rosenberger; V Smekal; P M Rommens; M Blauth
Journal:  Oper Orthop Traumatol       Date:  2011-12       Impact factor: 1.154

5.  Intramedullary tibial nailing of distal tibiofibular fractures: additional fibular fixation or not?

Authors:  M Van Maele; B Molenaers; E Geusens; S Nijs; H Hoekstra
Journal:  Eur J Trauma Emerg Surg       Date:  2017-06-05       Impact factor: 3.693

6.  [Intramedullary nailing of the tibia with the expert tibia nail].

Authors:  Matthias Hansen; René El Attal; Jochen Blum; Michael Blauth; Pol Maria Rommens
Journal:  Oper Orthop Traumatol       Date:  2009-12       Impact factor: 1.154

7.  Elastic nails for fibular fracture in adult tibiofibular fractures.

Authors:  Qiang Wang; Hong-Guang Xu; Yin-Chang Zhang; Li-Jun Dong
Journal:  Int J Clin Exp Med       Date:  2015-06-15

8.  Unreamed intramedullary nailing in distal tibial fractures.

Authors:  Khaled Hamed Salem
Journal:  Int Orthop       Date:  2013-07-28       Impact factor: 3.075

9.  Treatment of Distal Lower Leg Fractures: Results with Fixed-Angle Plate Osteosynthesis.

Authors:  Maximilian Faschingbauer; Benjamin Kienast; Arndt P Schulz; Rudolf Vukelic; Jan Meiners
Journal:  Eur J Trauma Emerg Surg       Date:  2009-11-16       Impact factor: 3.693

10.  Distal Tibial Fractures: Intramedullary Nailing.

Authors:  Andreas H Ruecker; Michael Hoffmann; Martin E Rupprecht; Johannes M Rueger
Journal:  Eur J Trauma Emerg Surg       Date:  2009-11-16       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.