Measurement of gastric emptying by the 13C-octanoate breath test--rationalization with scintigraphy.

Leslie J C Bluck1, W Andy Coward.   

Abstract

The (13)C-octanoate breath test has not achieved universal acceptance for the measurement of solid phase gastric emptying, largely because the results are not comparable with those from direct methods such as scintigraphy. To convert breath-test data to their scintigraphic equivalent scale corrections are applied which have been obtained from population studies, but there is no guarantee that these are applicable in all cases. We propose an alternative method applicable on an individual basis based upon a simple physiological model which does not require any change to the breath-test protocol. It is demonstrated by comparison with scintigraphy and the octanoate saliva test. Results from an existing dataset of simultaneous breath test, saliva test and scintigraphic determinations of solid phase gastric emptying from nine healthy subjects were re-analysed. The corrected breath tests gave gastric emptying curves which were shown to be not significantly different to those obtained from scintigraphy. The method provides a simple but effective way of generating gastric emptying curves from breath-test data that are directly comparable with direct measurement methods, which is advantageous since it allows the whole of the gastric emptying profile to be generated, not just values for the lag phase and half-emptying times.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16462014     DOI: 10.1088/0967-3334/27/3/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Structural identifiability analysis of pharmacokinetic models using DAISY: semi-mechanistic gastric emptying models for 13C-octanoic acid.

Authors:  Kayode Ogungbenro; Leon Aarons
Journal:  J Pharmacokinet Pharmacodyn       Date:  2011-02-24       Impact factor: 2.745

2.  Microgravity Simulated by the 6° Head-Down Tilt Bed Rest Test Increases Intestinal Motility but Fails to Induce Gastrointestinal Symptoms of Space Motion Sickness.

Authors:  Meher Prakash; Ron Fried; Oliver Götze; Francisca May; Petra Frings-Meuthen; Edwin Mulder; Judit Valentini; Mark Fox; Michael Fried; Werner Schwizer; Benjamin Misselwitz
Journal:  Dig Dis Sci       Date:  2015-06-09       Impact factor: 3.199

3.  Bayesian hierarchical methods to interpret the (13)C-octanoic acid breath test for gastric emptying.

Authors:  Leslie J C Bluck; Sarah J Jackson; Georgios Vlasakakis; Adrian Mander
Journal:  Digestion       Date:  2010-11-01       Impact factor: 3.216