Subjective and objective measures of image quality in digital fluoroscopy.

C Walsh1, A Dowling, A Meade, J Malone.   

Abstract

There are numerous methods for assessing image quality in diagnostic X ray. In our study we assessed how imaging quality assurance methods perform in practice. Physics assessments were based on IPEM protocols using Leeds test objects. Clinical assessment was based on a questionnaire. A total of 15 systems in three European locations were assessed, covering a range of image intensifier-TV digital fluoroscopy units. Analysis of 274 clinical questionnaires showed that clinical and physics assessments did not place systems in the same order, based on a given image quality parameter. In almost all the comparisons, low level correlation was measured for statistical comparison of rank order (rs < 0.3). However, broad agreement was observed between physics and clinical assessments for image quality associated with contrast and noise. This study emphasises the importance of maintaining links with clinical assessment, when developing quality assurance metrics, and measuring the mutual performance of clinical and physical assessments of image quality.

Mesh:

Year:  2006        PMID: 16461534     DOI: 10.1093/rpd/nci708

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality.

Authors:  Claude Bertrand Nauer; Christoph Zubler; Christian Weisstanner; Christof Stieger; Pascal Senn; Andreas Arnold
Journal:  Neuroradiology       Date:  2011-09-23       Impact factor: 2.804

2.  Diagnostic efficacy of handheld devices for emergency radiologic consultation.

Authors:  Rachel J Toomey; John T Ryan; Mark F McEntee; Michael G Evanoff; Dev P Chakraborty; Jonathan P McNulty; David J Manning; Edel M Thomas; Patrick C Brennan
Journal:  AJR Am J Roentgenol       Date:  2010-02       Impact factor: 3.959

3.  Monte Carlo-based noise compensation in coil intensity corrected endorectal MRI.

Authors:  Dorothy Lui; Amen Modhafar; Masoom A Haider; Alexander Wong
Journal:  BMC Med Imaging       Date:  2015-10-12       Impact factor: 1.930

4.  Occupational and Patient Radiation Dose and Quality Implications of Femoral Access Imaging During Coronary Angiography.

Authors:  Kelly Wilson-Stewart; Davide Fontanarosa; Eva Malacova; Steven Gett; Allan Kruger; Jamie V Trapp
Journal:  J Multidiscip Healthc       Date:  2021-07-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.