Literature DB >> 16461527

Reference levels in PTCA as a function of procedure complexity.

A Peterzol1, E Quai, R Padovani, G Bernardi, C J Kotre, A Dowling.   

Abstract

The multicentre assessment of a procedure complexity index (CI) for the introduction of reference levels (RLs) in percutaneous transluminal coronary angioplasties (PTCA) is presented here. PTCAs were investigated based on methodology proposed by Bernardi et al. Multiple linear stepwise regression analysis, including clinical, anatomical and technical factors, was performed to obtain fluoroscopy time predictors. Based on these regression coefficients, a scoring system was defined and CI obtained. CI was used to classify dose values into three groups: low, medium and high complexity procedures, since there was good correlation (r = 0.41; P < 0.001) between dose-area product (DAP) and CI. CI groups were determined by an ANOVA test, and the resulting DAP and fluoroscopy time third quartiles suggested as preliminary RLs in PTCA, as a function of procedure complexity. PTCA preliminary RLs for DAP are 54, 76 and 127 Gy cm2, and 12, 20 and 27 min for fluoroscopy time, for the three CI groups.

Entities:  

Mesh:

Year:  2006        PMID: 16461527     DOI: 10.1093/rpd/nci719

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

Review 2.  Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review.

Authors:  Kwang Pyo Kim; Donald L Miller
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

3.  Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty.

Authors:  V Sadick; W Reed; L Collins; N Sadick; R Heard; J Robinson
Journal:  Br J Radiol       Date:  2009-12-17       Impact factor: 3.039

4.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

5.  Patient radiation dose audits for fluoroscopically guided interventional procedures.

Authors:  Stephen Baiter; Marvin Rosenstein; Donald L Miller; Beth Schueler; David Spelic
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

  5 in total