Are new technologies always reducing patient doses in cardiac procedures?

A Trianni1, G Bernardi, R Padovani.   

Abstract

Dynamic digital flat-panel (FD) imaging technology is characterised by a higher sensitivity and image quality compared to image intensifier (II) technology. In this study, an angiography system based on II and one based on FD were compared with respect to system performance and impact of patient dose in interventional cardiology. When entrance surface air kerma rates are measured, the FD system requires a reduced dose rate, of up to 40%. For coronary angiography (CA), fluoroscopy time (FT) and dose-area product (DAP) were 4.3 +/- 5.0 min and 31.2 +/- 30.2 Gy cm2 on the II system and 4.4 +/- 3.8 min and 33.4 +/- 19.2 Gy cm2 with the FD system. For percutaneous transluminal coronary angiography, FT and DAP were 11.4 +/- 10.7 min and 52.1 +/- 45.0 Gy cm2 on II and 10.7 +/- 8.7 min and 66.9 +/- 54.4 Gy cm2 on DF. Data comparison suggests that reduced entrance dose rates do not automatically imply a reduction of patient dose in clinical practice.

Entities:  

Mesh:

Year:  2006        PMID: 16461516     DOI: 10.1093/rpd/nci747

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

1.  Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty.

Authors:  V Sadick; W Reed; L Collins; N Sadick; R Heard; J Robinson
Journal:  Br J Radiol       Date:  2009-12-17       Impact factor: 3.039

2.  The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Rita Fossaceca; Marco Brambilla; Giuseppe Guzzardi; Paolo Cerini; Alessandra Renghi; Serena Valzano; Piero Brustia; Alessandro Carriero
Journal:  Eur Radiol       Date:  2012-05-23       Impact factor: 5.315

3.  Optimisation in fluoroscopy.

Authors:  B Axelsson
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

4.  Radiation dose reference card for interventional radiology procedures: Experience in a tertiary referral centre.

Authors:  Anna Varghese; Shyamkumar N Keshava; Vinu Moses; George Koshy; Suraj Mammen; Munawwar Ahmed; Roshan S Livingstone
Journal:  Indian J Radiol Imaging       Date:  2019-10-30

5.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01

6.  Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose.

Authors:  Roshan S Livingstone; David Chase; Anna Varghese; Paul V George; Oommen K George
Journal:  J Med Phys       Date:  2015 Jan-Mar