Literature DB >> 16460285

The contribution of biophysical lung injury to the development of biotrauma.

Claudia C dos Santos1, Arthur S Slutsky.   

Abstract

Patients with severe acute respiratory distress syndrome who die usually succumb to multiorgan failure as opposed to hypoxia. Despite appropriate resuscitation, some patients' symptoms persist on a downward spiral, apparently propagated by an uncontained systemic inflammatory response. This phenomenon is not well understood. However, a novel hypothesis to explain this observation proposes that it is related to the life-saving ventilatory support used to treat the respiratory failure. According to this hypothesis, mechanical ventilation per se, by altering both the magnitude and the pattern of lung stretch, can cause changes in gene expression and/or cellular metabolism that ultimately can lead to the development of an overwhelming inflammatory response-even in the absence of overt structural damage. This mechanism of injury has been termed biotrauma. In this review we explore the biotrauma hypothesis, the causal relationship between biophysical injury and organ failure, and its implications for the future therapy and management of critically ill patients.

Entities:  

Mesh:

Year:  2006        PMID: 16460285     DOI: 10.1146/annurev.physiol.68.072304.113443

Source DB:  PubMed          Journal:  Annu Rev Physiol        ISSN: 0066-4278            Impact factor:   19.318


  57 in total

1.  Assisted ventilation modes reduce the expression of lung inflammatory and fibrogenic mediators in a model of mild acute lung injury.

Authors:  Felipe Saddy; Gisele P Oliveira; Cristiane S N B Garcia; Liliane M Nardelli; Andreia F Rzezinski; Debora S Ornellas; Marcelo M Morales; Vera L Capelozzi; Paolo Pelosi; Patricia R M Rocco
Journal:  Intensive Care Med       Date:  2010-03-24       Impact factor: 17.440

2.  PEEP/ FIO2 ARDSNet Scale Grouping of a Single Ventilator for Two Patients: Modeling Tidal Volume Response.

Authors:  Vitaly O Kheyfets; Steven R Lammers; Jennifer Wagner; Karsten Bartels; Jerome Piccoli; Bradford J Smith
Journal:  Respir Care       Date:  2020-08       Impact factor: 2.258

Review 3.  Effects of mechanical ventilation on the extracellular matrix.

Authors:  Paolo Pelosi; Patricia R Rocco
Journal:  Intensive Care Med       Date:  2008-02-09       Impact factor: 17.440

4.  Understanding high-frequency oscillation: lessons from the animal kingdom.

Authors:  Niall D Ferguson; Jesús Villar; Arthur S Slutsky
Journal:  Intensive Care Med       Date:  2007-06-12       Impact factor: 17.440

5.  Renal hypoperfusion and impaired endothelium-dependent vasodilation in an animal model of VILI: the role of the peroxynitrite-PARP pathway.

Authors:  Rosanna Vaschetto; Jan W Kuiper; René J P Musters; Etto C Eringa; Francesco Della Corte; Kanneganti Murthy; A B Johan Groeneveld; Frans B Plötz
Journal:  Crit Care       Date:  2010-03-26       Impact factor: 9.097

6.  Modeling the Progression of Epithelial Leak Caused by Overdistension.

Authors:  Katharine L Hamlington; Baoshun Ma; Bradford J Smith; Jason H T Bates
Journal:  Cell Mol Bioeng       Date:  2016-01-19       Impact factor: 2.321

7.  Differential Effects of Intraoperative Positive End-expiratory Pressure (PEEP) on Respiratory Outcome in Major Abdominal Surgery Versus Craniotomy.

Authors:  Myrthe A C de Jong; Karim S Ladha; Marcos F Vidal Melo; Anne Kathrine Staehr-Rye; Edward A Bittner; Tobias Kurth; Matthias Eikermann
Journal:  Ann Surg       Date:  2016-08       Impact factor: 12.969

8.  Regional lung aeration and ventilation during pressure support and biphasic positive airway pressure ventilation in experimental lung injury.

Authors:  Marcelo Gama de Abreu; Maximiliano Cuevas; Peter M Spieth; Alysson R Carvalho; Volker Hietschold; Christian Stroszczynski; Bärbel Wiedemann; Thea Koch; Paolo Pelosi; Edmund Koch
Journal:  Crit Care       Date:  2010-03-16       Impact factor: 9.097

9.  Inhaled activated protein C protects mice from ventilator-induced lung injury.

Authors:  Nikolaos A Maniatis; Eleftheria Letsiou; Stylianos E Orfanos; Matina Kardara; Ioanna Dimopoulou; Georgios Nakos; Marilena E Lekka; Charalambos Roussos; Apostolos Armaganidis; Anastasia Kotanidou
Journal:  Crit Care       Date:  2010-04-19       Impact factor: 9.097

10.  Mechanical ventilation with high tidal volume induces inflammation in patients without lung disease.

Authors:  Roselaine Pinheiro de Oliveira; Marcio Pereira Hetzel; Mauro dos Anjos Silva; Daniele Dallegrave; Gilberto Friedman
Journal:  Crit Care       Date:  2010-03-18       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.